Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 197

The DOI matches its Crossref record.

Accuracy and precision of quantitative assessment of cartilage morphology by magnetic resonance imaging at 3.0T

Eckstein, Felix, Charles, H. Cecil, Buck, Robert J., Kraus, Virginia B., Remmers, Ann E., Hudelmaier, Martin, Wirth, Wolfgang, Evelhoch, Jeffrey L.·2005·Arthritis & Rheumatism

Abstract

Objective: Quantitative magnetic resonance imaging (MRI) of articular cartilage represents a powerful tool in osteoarthritis (OA) research, but has so far been confined to a field strength of 1.5T. The aim of this study was to evaluate the precision of quantitative MRI assessments of human cartilage morphology at 3.0T and to correlate the measurements at 3.0T with validated measurements at 1.5T. Methods: MR images of the knee of 15 participants with OA and 15 healthy control subjects were acquired using Siemens 1.5T and 3.0T scanners. Double oblique coronal scans were obtained at 1.5T with a 1.5‐mm partition thickness, at 3.0T with a 1.5‐mm partition thickness, and at 3.0T with a 1.0‐mm partition thickness. Cartilage volume, thickness, and surface area of the femorotibial cartilage plates were quantified using proprietary software. Results: For 1.5‐mm partition thickness at 1.5T, the precision error was 3.0% and 2.6% for cartilage volume and cartilage thickness, respectively. The error was smaller for a 1.5‐mm partition thickness at 3.0T (2.6% and 2.5%) and still smaller for a 1.0‐mm partition thickness at 3.0T (2.1% and 2.0%). Correlation coefficients between values obtained at 3.0T and 1.5T were high (r ≥ 0.96), with no significant deviation between the two field strengths. Conclusion: Quantitative MRI measurement of cartilage morphology at 3.0T (partition thickness 1 mm) was found to be accurate and tended to be more reproducible than at 1.5T (partition thickness 1.5 mm). Imaging at 3.0T may therefore provide superior ability to detect changes in cartilage status over time and to determine responses to treatment with structure‐modifying drugs.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/art.21348

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 197

Metadata

Authors
Eckstein, F., Charles, H. C., Buck, R. J., Kraus, V. B., Remmers, A. E., Hudelmaier, M., Wirth, W., & Evelhoch, J. L.
Venue
Arthritis & Rheumatism
Publisher
Wiley
Published
2005-09-30
Volume
52
Issue
10
Pages
3132-3136
ISSN
  • 0004-3591 (ISSN-L)
  • 1529-0131
OpenAlex
W2017022352
Cited by
197
References
0
FWCI
10.52
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Accuracy and precision of quantitative assessment of cartilage morphology by magnetic resonance imaging at 3.0T. https://app.cochat.ai/papers/10.1002/art.21348
The paper
Eckstein, F., Charles, H. C., Buck, R. J., Kraus, V. B., Remmers, A. E., Hudelmaier, M., Wirth, W., & Evelhoch, J. L. (2005). Accuracy and precision of quantitative assessment of cartilage morphology by magnetic resonance imaging at 3.0T. Arthritis & Rheumatism. https://doi.org/10.1002/art.21348

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.