Contribution of salivary gland ultrasonography to the diagnosis of Sjögren's syndrome: Toward new diagnostic criteria?
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Objective: To determine the accuracy of salivary gland ultrasonography (SGUS) for diagnosing primary Sjögren's syndrome (SS) and to suggest modifications of the American–European Consensus Group (AECG) classification criteria. Methods: We conducted a cross‐sectional study in a prospective cohort of patients with suspected primary SS that was established between 2006 and 2011. The echostructure of the bilateral parotid and submandibular glands was graded from 0 to 4, and the gland size was measured; blood flow to the parotid gland was assessed using Doppler waveform analysis. The reference standard was a clinical diagnosis of primary SS as determined by a group of experts blinded to the results of SGUS. Receiver operating characteristic (ROC) curve analysis was performed to compare the diagnostic value of the 0–4‐point echostructure grade for each of the 4 major salivary glands, the sum of the grades for the 4 glands, and the highest grade among the 4 glands. Results: Of the 158 patients in the study, 78 had a diagnosis of primary SS according to the experts, including 61 patients (78.2%) who met the AECG criteria. Doppler waveform analysis and gland size measurement showed poor diagnostic performance. The results of ROC curve analysis showed that the highest grade among the 4 glands provided the best diagnostic value. The optimal grade cutoff was 2 (62.8% sensitivity and 95.0% specificity). A weighted score was constructed using scores for the 5 variables selected by logistic regression analysis, as follows: (salivary flow × 1.5) + (Schirmer's test × 1.5) + (salivary gland biopsy × 3) + (SSA/SSB × 4.5) + (SGUS × 2). According to ROC curve analysis, a score of ≥5 of 12.5 had 85.7% sensitivity and 94.9% specificity, compared with 77.9% sensitivity and 98.7% specificity for the AECG criteria. The addition of SGUS to the AECG criteria increased sensitivity to 87.0% but did not change specificity. Conclusion: Modifications of the AECG criteria, including the addition of a SGUS score, notably improved diagnostic performance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Two Further Applications of a Model for Binary Regression
Cox, D. R. (1958) · Biometrika · doi:10.2307/2333203 · Cited by 557
Two further applications of a model for binary regression
COX, D. R. (1958) · Biometrika · doi:10.1093/biomet/45.3-4.562 · Cited by 556
Validation of probabilistic predictions
Miller, M. E., Langefeld, C. D., Tierney, W. M., Hui, S. L., & McDonald, C. J. (1993) · Medical Decision Making · doi:10.1177/0272989x9301300107 · Cited by 129
Cited by
Fisher, B. A., Jonsson, R., Daniels, T., Bombardieri, M., Brown, R. M., Morgan, P., Bombardieri, S., Ng, W.-F., Tzioufas, A. G., Vitali, C., et al. (2017) · Annals of the Rheumatic Diseases · doi:10.1136/annrheumdis-2016-210448 · Cited by 311
Self-citation
Metadata
- Authors
- Cornec, D., Jousse‐Joulin, S., Pers, J., Marhadour, T., Cochener, B., Boisramé‐Gastrin, S., Nowak, E., Youinou, P., Saraux, A., & Devauchelle‐Pensec, V.
- Venue
- Arthritis & Rheumatism
- Publisher
- Wiley
- Published
- 2012-12-27
- Volume
- 65
- Issue
- 1
- Pages
- 216-225
- ISSN
- 0004-3591 (ISSN-L)
- 1529-0131
- OpenAlex
- W1994014825
- Cited by
- 229
- References
- 3
- FWCI
- 10.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Contribution of salivary gland ultrasonography to the diagnosis of Sjögren's syndrome: Toward new diagnostic criteria? https://app.cochat.ai/papers/10.1002/art.37698
- The paper
- Cornec, D., Jousse‐Joulin, S., Pers, J., Marhadour, T., Cochener, B., Boisramé‐Gastrin, S., Nowak, E., Youinou, P., Saraux, A., & Devauchelle‐Pensec, V. (2013). Contribution of salivary gland ultrasonography to the diagnosis of Sjögren's syndrome: Toward new diagnostic criteria? Arthritis & Rheumatism. https://doi.org/10.1002/art.37698
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.