Effective Cancer Cell Killing by Hydrophobic Nanovoid‐Enhanced Cavitation under Safe Low‐Energy Ultrasound
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
β‐Cyclodextrin (β‐CD)‐capped mesoporous silica nanoparticles with hydrophobic internal nanovoids were prepared and used for effective cancer cell killing in synergistic combination with low‐energy ultrasound (≤1.0 W cm−2, 1 MHz). The water‐dispersible nanoparticles with hydrophobic internal nanovoids can be taken up by cancer cells and subsequently evoke a remarkable cavitation effect under irradiation with mild low‐energy ultrasound (≤1.0 W cm−2, 1 MHz). A significant cancer cell killing effect was observed in cancer cells and in a mouse xenograft tumor model treated with the nanoagents together with the low‐energy ultrasound, showing a distinct dependence on the concentration of nanoagents and ultrasound intensity. By contrast, an antitumor effect was not observed when either low‐energy ultrasound or nanoagents were applied alone. These findings are significant as the technique promises a safe, low‐cost, and effective treatment for cancer therapy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nicolas, J., Mura, S., Brambilla, D., Mackiewicz, N., & Couvreur, P. (2013) · Chem. Soc. Rev. · doi:10.1039/c2cs35265f · Cited by 1,270
Cited by
Nanotechnology in hyperthermia cancer therapy: From fundamental principles to advanced applications
Beik, J., Abed, Z., Ghoreishi, F. S., Hosseini-Nami, S., Mehrzadi, S., Shakeri-Zadeh, A., & Kamrava, S. K. (2016) · Journal of Controlled Release · doi:10.1016/j.jconrel.2016.05.062 · Cited by 579
Ultrasound‐Activated Sensitizers and Applications
Lin, X., Song, J., Chen, X., & Yang, H. (2020) · Angewandte Chemie International Edition · doi:10.1002/anie.201906823 · Cited by 501
Nanoparticle-assisted ultrasound: A special focus on sonodynamic therapy against cancer
Canavese, G., Ancona, A., Racca, L., Canta, M., Dumontel, B., Barbaresco, F., Limongi, T., & Cauda, V. (2018) · Chemical Engineering Journal · doi:10.1016/j.cej.2018.01.060 · Cited by 457
Multifunctional mesoporous silica nanoparticles for biomedical applications
Xu, B., Li, S., Shi, R., & Liu, H. (2023) · Signal Transduction and Targeted Therapy · doi:10.1038/s41392-023-01654-7 · Cited by 433
Ultrasound-responsive systems as components for smart materials
Athanassiadis, A. G., Ma, Z., Moreno-Gomez, N., Melde, K., Choi, E., Goyal, R., & Fischer, P. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00622 · Cited by 293
Metadata
- Authors
- Zhao, Y., Zhu, Y., Fu, J., & Wang, L.
- Venue
- Chemistry – An Asian Journal
- Publisher
- Wiley
- Published
- 2013-12-11
- Volume
- 9
- Issue
- 3
- Pages
- 790-796
- ISSN
- 1861-471X (ISSN-L)
- 1861-4728
- OpenAlex
- W2095969464
- Cited by
- 45
- References
- 1
- FWCI
- 1.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effective Cancer Cell Killing by Hydrophobic Nanovoid‐Enhanced Cavitation under Safe Low‐Energy Ultrasound. https://app.cochat.ai/papers/10.1002/asia.201301333
- The paper
- Zhao, Y., Zhu, Y., Fu, J., & Wang, L. (2014). Effective Cancer Cell Killing by Hydrophobic Nanovoid‐Enhanced Cavitation under Safe Low‐Energy Ultrasound. Chemistry – An Asian Journal. https://doi.org/10.1002/asia.201301333
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.