Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 2

The DOI matches its Crossref record; the references it cites are not checked yet.

Fabrication of Polypyrrole–Polystyrene Sulfonate by Amperometric Biosensor‐Based Electropolymerization for Cholesterol Determination in Serum

Dada, Alaa Anwer Ali, Yildirim, Ertan, Muhammed, Sinan Mithat, Çete, Servet·2025·Biotechnology and Applied Biochemistry

Abstract

Since cholesterol triggers many diseases, many methods have been developed for its determination. In this study, an alternative system for cholesterol determination was developed by preparing amperometric biosensors. In the development of the biosensor, Pt/polypyrrole–polystyrene sulfonate film was prepared by electropolymerization of polypyrrole in polystyrene sulfonate medium using platinum surfaces. The cholesterol oxidase enzyme was immobilized on the prepared platinum/polypyrrole–polystyrene sulfonate electrode. For molecular determination in the prepared cholesterol biosensor, a series of enzymatic reactions were performed on the enzyme electrode surface at +0.40 V by utilizing the oxidation of hydrogen peroxide. The effects of environmental conditions such as temperature and pH that affect the performance of the biosensor were investigated, and the most suitable conditions for the biosensor were determined. The linear working range of the amperometric biosensor for cholesterol determination was determined. In enzyme immobilization, calculations were made for the Michaelis–Menten constants Km and Vmax values. Storage life and reproducibility of cholesterol biosensor were determined. Cholesterol determination in biological fluid (blood) was performed with the prepared biosensor. The fact that the fabricated amperometric‐based cholesterol biosensor can be used for the diagnosis of many diseases is important in terms of early diagnosis in the future.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/bab.2742

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

The citation lists haven’t been fetched yet

Cited by 2

Research works printed but not linked: 39

  1. 10.3390/bios13110976 · DOI
  2. 10.1016/j.aca.2003.09.064 · doi:10.1016/j.aca.2003.09.064
  3. 10.1007/s10008-021-04939-5 · DOI
  4. 10.1007/s10008-021-05107-5 · DOI
  5. 10.1007/s11696-019-00907-6 · DOI
  6. 10.1134/S1023193521100049 · DOI
  7. 10.1016/j.eurpolymj.2007.05.021 · doi:10.1016/j.eurpolymj.2007.05.021
  8. 10.1007/s10008-020-04715-x · doi:10.1007/s10008-020-04715-x
  9. 10.1080/10408347.2018.1461552 · DOI
  10. 10.1016/S0925-4005(99)00025-8 · doi:10.1016/s0925-4005(99)00025-8
  11. 10.1016/j.bios.2004.09.005 · doi:10.1016/j.bios.2004.09.005
  12. 10.1074/jbc.M104103200 · doi:10.1074/jbc.m104103200
  13. 10.1016/B978-0-12-819667-0.00006-8 · DOI
  14. 10.1002/app.26198 · DOI
  15. 10.3109/10731190903356453 · doi:10.3109/10731190903356453
  16. Katrlik J., 2005, Interference‐Free Amperometric Biosensor for Direct Cholesterol Determination, ACTA Facultatis Pharmaceutiae Universitatis Comenianae, Tomas
  17. 10.1016/S1567-1739(02)00178-5 · doi:10.1016/s1567-1739(02)00178-5
  18. 10.1016/S0003-2670(98)00213-X · doi:10.1016/s0003-2670(98)00213-x
  19. 10.1016/j.molcatb.2010.06.002 · doi:10.1016/j.molcatb.2010.06.002
  20. 10.1016/S0039-9140(03)00303-5 · doi:10.1016/s0039-9140(03)00303-5
  21. 10.1016/S0925-4005(98)00258-5 · doi:10.1016/s0925-4005(98)00258-5
  22. 10.1248/cpb.39.2745 · doi:10.1248/cpb.39.2745
  23. 10.1016/j.aca.2007.09.028 · DOI
  24. 10.3109/21691401.2012.759121 · DOI
  25. 10.1016/j.colsurfa.2004.01.028 · DOI
  26. 10.1080/10731190600684116 · DOI
  27. 10.3390/s90806435 · DOI
  28. 10.1007/s10008-008-0590-7 · doi:10.1007/s10008-008-0590-7
  29. 10.1016/j.aca.2005.10.008 · DOI
  30. 10.1016/S0956-5663(01)00312-8 · DOI · Paper page
  31. 10.1016/j.aca.2006.09.010 · doi:10.1016/j.aca.2006.09.010
  32. 10.1016/S0039-9140(99)00311-2 · doi:10.1016/s0039-9140(99)00311-2
  33. 10.1039/an9941900833 · doi:10.1039/an9941900833
  34. 10.1080/00032719408006342 · doi:10.1080/00032719408006342
  35. 10.1016/S0003-2670(02)01484-8 · DOI
  36. 10.1016/j.ab.2004.10.040 · doi:10.1016/j.ab.2004.10.040
  37. 10.1016/j.jelechem.2016.06.033 · DOI
  38. 10.1039/C6GC00507A · doi:10.1039/c6gc00507a
  39. 10.1016/j.snb.2022.131939 · doi:10.1016/j.snb.2022.131939

Metadata

Authors
Dada, A. A. A., Yildirim, E., Muhammed, S. M., & Çete, S.
Venue
Biotechnology and Applied Biochemistry
Publisher
Wiley
Published
2025-03-11
Volume
72
Issue
5
Pages
1330-1340
ISSN
  • 0885-4513
  • 1470-8744
Cited by
2
Language
en

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Fabrication of Polypyrrole–Polystyrene Sulfonate by Amperometric Biosensor‐Based Electropolymerization for Cholesterol Determination in Serum. https://app.cochat.ai/papers/10.1002/bab.2742
The paper
Dada, A. A. A., Yildirim, E., Muhammed, S. M., & Çete, S. (2025). Fabrication of Polypyrrole–Polystyrene Sulfonate by Amperometric Biosensor‐Based Electropolymerization for Cholesterol Determination in Serum. Biotechnology and Applied Biochemistry. https://doi.org/10.1002/bab.2742

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.