The DOI matches its Crossref record; the references it cites are not checked yet.
Fabrication of Polypyrrole–Polystyrene Sulfonate by Amperometric Biosensor‐Based Electropolymerization for Cholesterol Determination in Serum
Abstract
Since cholesterol triggers many diseases, many methods have been developed for its determination. In this study, an alternative system for cholesterol determination was developed by preparing amperometric biosensors. In the development of the biosensor, Pt/polypyrrole–polystyrene sulfonate film was prepared by electropolymerization of polypyrrole in polystyrene sulfonate medium using platinum surfaces. The cholesterol oxidase enzyme was immobilized on the prepared platinum/polypyrrole–polystyrene sulfonate electrode. For molecular determination in the prepared cholesterol biosensor, a series of enzymatic reactions were performed on the enzyme electrode surface at +0.40 V by utilizing the oxidation of hydrogen peroxide. The effects of environmental conditions such as temperature and pH that affect the performance of the biosensor were investigated, and the most suitable conditions for the biosensor were determined. The linear working range of the amperometric biosensor for cholesterol determination was determined. In enzyme immobilization, calculations were made for the Michaelis–Menten constants Km and Vmax values. Storage life and reproducibility of cholesterol biosensor were determined. Cholesterol determination in biological fluid (blood) was performed with the prepared biosensor. The fact that the fabricated amperometric‐based cholesterol biosensor can be used for the diagnosis of many diseases is important in terms of early diagnosis in the future.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
The citation lists haven’t been fetched yet
Cited by 2
Research works printed but not linked: 39
- 10.3390/bios13110976 · DOI
- 10.1016/j.aca.2003.09.064 · doi:10.1016/j.aca.2003.09.064
- 10.1007/s10008-021-04939-5 · DOI
- 10.1007/s10008-021-05107-5 · DOI
- 10.1007/s11696-019-00907-6 · DOI
- 10.1134/S1023193521100049 · DOI
- 10.1016/j.eurpolymj.2007.05.021 · doi:10.1016/j.eurpolymj.2007.05.021
- 10.1007/s10008-020-04715-x · doi:10.1007/s10008-020-04715-x
- 10.1080/10408347.2018.1461552 · DOI
- 10.1016/S0925-4005(99)00025-8 · doi:10.1016/s0925-4005(99)00025-8
- 10.1016/j.bios.2004.09.005 · doi:10.1016/j.bios.2004.09.005
- 10.1074/jbc.M104103200 · doi:10.1074/jbc.m104103200
- 10.1016/B978-0-12-819667-0.00006-8 · DOI
- 10.1002/app.26198 · DOI
- 10.3109/10731190903356453 · doi:10.3109/10731190903356453
- Katrlik J., 2005, Interference‐Free Amperometric Biosensor for Direct Cholesterol Determination, ACTA Facultatis Pharmaceutiae Universitatis Comenianae, Tomas
- 10.1016/S1567-1739(02)00178-5 · doi:10.1016/s1567-1739(02)00178-5
- 10.1016/S0003-2670(98)00213-X · doi:10.1016/s0003-2670(98)00213-x
- 10.1016/j.molcatb.2010.06.002 · doi:10.1016/j.molcatb.2010.06.002
- 10.1016/S0039-9140(03)00303-5 · doi:10.1016/s0039-9140(03)00303-5
- 10.1016/S0925-4005(98)00258-5 · doi:10.1016/s0925-4005(98)00258-5
- 10.1248/cpb.39.2745 · doi:10.1248/cpb.39.2745
- 10.1016/j.aca.2007.09.028 · DOI
- 10.3109/21691401.2012.759121 · DOI
- 10.1016/j.colsurfa.2004.01.028 · DOI
- 10.1080/10731190600684116 · DOI
- 10.3390/s90806435 · DOI
- 10.1007/s10008-008-0590-7 · doi:10.1007/s10008-008-0590-7
- 10.1016/j.aca.2005.10.008 · DOI
- 10.1016/S0956-5663(01)00312-8 · DOI · Paper page
- 10.1016/j.aca.2006.09.010 · doi:10.1016/j.aca.2006.09.010
- 10.1016/S0039-9140(99)00311-2 · doi:10.1016/s0039-9140(99)00311-2
- 10.1039/an9941900833 · doi:10.1039/an9941900833
- 10.1080/00032719408006342 · doi:10.1080/00032719408006342
- 10.1016/S0003-2670(02)01484-8 · DOI
- 10.1016/j.ab.2004.10.040 · doi:10.1016/j.ab.2004.10.040
- 10.1016/j.jelechem.2016.06.033 · DOI
- 10.1039/C6GC00507A · doi:10.1039/c6gc00507a
- 10.1016/j.snb.2022.131939 · doi:10.1016/j.snb.2022.131939
Metadata
- Authors
- Dada, A. A. A., Yildirim, E., Muhammed, S. M., & Çete, S.
- Venue
- Biotechnology and Applied Biochemistry
- Publisher
- Wiley
- Published
- 2025-03-11
- Volume
- 72
- Issue
- 5
- Pages
- 1330-1340
- ISSN
- 0885-4513
- 1470-8744
- Cited by
- 2
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fabrication of Polypyrrole–Polystyrene Sulfonate by Amperometric Biosensor‐Based Electropolymerization for Cholesterol Determination in Serum. https://app.cochat.ai/papers/10.1002/bab.2742
- The paper
- Dada, A. A. A., Yildirim, E., Muhammed, S. M., & Çete, S. (2025). Fabrication of Polypyrrole–Polystyrene Sulfonate by Amperometric Biosensor‐Based Electropolymerization for Cholesterol Determination in Serum. Biotechnology and Applied Biochemistry. https://doi.org/10.1002/bab.2742
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.