Uniform magnetic fields and double‐wrapped coil systems: Improved techniques for the design of bioelectromagnetic experiments
Abstract
A common mistake in biomagnetic experimentation is the assumption that Helmholtz coils provide uniform magnetic fields; this is true only for a limited volume at their center. Substantial improvements on this design have been made during the past 140 years with systems of three, four, and five coils. Numerical comparisons of the field uniformity generated by these designs are made here, along with a table of construction details and recommendations for their use in experiments in which large volumes of uniform intensity magnetic exposures are needed. Double‐wrapping, or systems of bifilar windings, can also help control for the non‐magnetic effects of the electric coils used in many experiments. In this design, each coil is wrapped in parallel with two separate, adjacent strands of copper wire, rather than the single strand used normally. If currents are flowing in antiparallel directions, the magnetic fields generated by each strand will cancel and yield virtually no external magnetic field, whereas parallel currents will yield an external field. Both cases will produce similar non‐magnetic effects of ohmic heating, and simple measures can reduce the small vibration and electric field differences. Control experiments can then be designed such that the only major difference between treated and untreated groups is the presence or absence of the magnetic field. Double‐wrapped coils also facilitate the use of truly double‐blind protocol, as the same apparatus can be used either for experimental or control groups. 1992 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Role of duplicate genes in genetic robustness against null mutations
Gu, Z., Steinmetz, L. M., Gu, X., Scharfe, C., Davis, R. W., & Li, W.-H. (2003) · Nature · doi:10.1038/nature01198 · Cited by 889
Cryptochrome mediates light-dependent magnetosensitivity in Drosophila
Gegear, R. J., Casselman, A., Waddell, S., & Reppert, S. M. (2008) · Nature · doi:10.1038/nature07183 · Cited by 421
Anthropogenic electromagnetic noise disrupts magnetic compass orientation in a migratory bird
Engels, S., Schneider, N.-L., Lefeldt, N., Hein, C. M., Zapka, M., Michalik, A., Elbers, D., Kittel, A., Hore, P. J., & Mouritsen, H. (2014) · Nature · doi:10.1038/nature13290 · Cited by 403
Effects of Electromagnetic Fields on Molecules and Cells
Goodman, E. M., Greenebaum, B., & Marron, M. T. (1995) · International Review of Cytology · doi:10.1016/s0074-7696(08)62489-4 · Cited by 304
Regional Magnetic Fields as Navigational Markers for Sea Turtles
Lohmann, K. J., Cain, S. D., Dodge, S. A., & Lohmann, C. M. F. (2001) · Science · doi:10.1126/science.1064557 · Cited by 296
Metadata
- Authors
- Kirschvink, J. L.
- Venue
- Bioelectromagnetics
- Publisher
- Wiley
- Published
- 1992-01
- Volume
- 13
- Issue
- 5
- Pages
- 401-411
- ISSN
- 0197-8462 (ISSN-L)
- 1521-186X
- OpenAlex
- W2136518918
- Cited by
- 359
- References
- 0
- FWCI
- 6.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Uniform magnetic fields and double‐wrapped coil systems: Improved techniques for the design of bioelectromagnetic experiments. https://app.cochat.ai/papers/10.1002/bem.2250130507
- The paper
- Kirschvink, J. L. (1992). Uniform magnetic fields and double‐wrapped coil systems: Improved techniques for the design of bioelectromagnetic experiments. Bioelectromagnetics. https://doi.org/10.1002/bem.2250130507
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.