The DOI matches its Crossref record.
Periodic counter‐current chromatography – design and operational considerations for integrated and continuous purification of proteins
Abstract
Integrated and continuous processing of recombinant proteins offers several advantages over batch or semi‐batch processing used traditionally in the biotechnology industry. This paper presents a theoretical and practical approach for designing a periodic counter‐current chromatography (PCC) operation as a continuous capture purification step that is integrated with a perfusion cell culture process. The constraints for continuous and optimal PCC operation govern the selection of residence time and number of columns. The flexibility available in PCC design for selection of these parameters is dictated by the binding characteristics of the target protein on the capture resin. Using an empirical model for the protein breakthrough curve, analytical solutions to determine these conditions were derived and verified with experimental results for three different proteins: two relatively unstable proteins (recombinant enzymes) and a relatively stable protein (monoclonal antibody). The advantages of a continuous downstream capture step are highlighted for the three case studies in comparison with the existing batch chromatography processes. The use of PCC leads to improvements in process economics due to higher resin capacity utilization and correspondingly lower buffer consumption. Furthermore, integrated and continuous bioprocessing results in a smaller facility footprint by elimination of harvest hold vessels and clarification, as well as by reducing the capture column size by one to two orders of magnitude.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Continuous downstream processing for high value biological products: A Review
Zydney, A. L. (2016) · Biotechnology and Bioengineering · doi:10.1002/bit.25695 · Cited by 302
Current challenges in biotherapeutic particles manufacturing
Moleirinho, M. G., Silva, R. J. S., Alves, P. M., Carrondo, M. J. T., & Peixoto, C. (2020) · Expert Opinion on Biological Therapy · doi:10.1080/14712598.2020.1693541 · Cited by 123
Helgers, H., Schmidt, A., Lohmann, L. J., Vetter, F. L., Juckers, A., Jensch, C., Mouellef, M., Zobel-Roos, S., & Strube, J. (2021) · Processes · doi:10.3390/pr9010172 · Cited by 52
Continuous integrated manufacturing for biopharmaceuticals: A new paradigm or an empty promise?
Rathore, A. S., Thakur, G., & Kateja, N. (2023) · Biotechnology and Bioengineering · doi:10.1002/bit.28235 · Cited by 41
Recent advances in automated protein design and its future challenges
Setiawan, D., Brender, J., & Zhang, Y. (2018) · Expert Opinion on Drug Discovery · doi:10.1080/17460441.2018.1465922 · Cited by 26
Metadata
- Authors
- Godawat, R., Brower, K., Jain, S., Konstantinov, K., Riske, F., & Warikoo, V.
- Venue
- Biotechnology Journal
- Publisher
- Wiley
- Published
- 2012-11-09
- Volume
- 7
- Issue
- 12
- Pages
- 1496-1508
- ISSN
- 1860-6768 (ISSN-L)
- 1860-7314
- OpenAlex
- W2142397163
- Cited by
- 200
- References
- 0
- FWCI
- 4.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Periodic counter‐current chromatography – design and operational considerations for integrated and continuous purification of proteins. https://app.cochat.ai/papers/10.1002/biot.201200068
- The paper
- Godawat, R., Brower, K., Jain, S., Konstantinov, K., Riske, F., & Warikoo, V. (2012). Periodic counter‐current chromatography – design and operational considerations for integrated and continuous purification of proteins. Biotechnology Journal. https://doi.org/10.1002/biot.201200068
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.