The DOI matches its Crossref record.
Microfluidic‐integrated biosensors: Prospects for point‐of‐care diagnostics
Abstract
There is a growing demand to integrate biosensors with microfluidics to provide miniaturized platforms with many favorable properties, such as reduced sample volume, decreased processing time, low cost analysis and low reagent consumption. These microfluidics‐integrated biosensors would also have numerous advantages such as laminar flow, minimal handling of hazardous materials, multiple sample detection in parallel, portability and versatility in design. Microfluidics involves the science and technology of manipulation of fluids at the micro‐ to nano‐liter level. It is predicted that combining biosensors with microfluidic chips will yield enhanced analytical capability, and widen the possibilities for applications in clinical diagnostics. The recent developments in microfluidics have helped researchers working in industries and educational institutes to adopt some of these platforms for point‐of‐care (POC) diagnostics. This review focuses on the latest advancements in the fields of microfluidic biosensing technologies, and on the challenges and possible solutions for translation of this technology for POC diagnostic applications. We also discuss the fabrication techniques required for developing microfluidic‐integrated biosensors, recently reported biomarkers, and the prospects of POC diagnostics in the medical industry.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Biosensors and bioelectronics on smartphone for portable biochemical detection
Zhang, D., & Liu, Q. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.08.037 · Cited by 647
Optical Biosensors for the Detection of Pathogenic Microorganisms
Yoo, S. M., & Lee, S. Y. (2016) · Trends in Biotechnology · doi:10.1016/j.tibtech.2015.09.012 · Cited by 571
Costa, C. M., Cardoso, V. F., Martins, P., Correia, D. M., Gonçalves, R., Costa, P., Correia, V., Ribeiro, C., Fernandes, M. M., Martins, P. M., et al. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00196 · Cited by 498
Electrochemical biosensors and nanobiosensors
Hammond, J. L., Formisano, N., Estrela, P., Carrara, S., & Tkac, J. (2016) · Essays in Biochemistry · doi:10.1042/ebc20150008 · Cited by 425
Malhotra, B. D., & Ali, M. A. (2018) · Nanomaterials for Biosensors · doi:10.1016/b978-0-323-44923-6.00001-7 · Cited by 319
Self-citation
Metadata
- Authors
- Kumar, S., Kumar, S., Ali, M. A., Anand, P., Agrawal, V. V., John, R., Maji, S., & Malhotra, B. D.
- Venue
- Biotechnology Journal
- Publisher
- Wiley
- Published
- 2013-09-06
- Volume
- 8
- Issue
- 11
- Pages
- 1267-1279
- ISSN
- 1860-6768 (ISSN-L)
- 1860-7314
- OpenAlex
- W2020678155
- Cited by
- 199
- References
- 0
- FWCI
- 8.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Microfluidic‐integrated biosensors: Prospects for point‐of‐care diagnostics. https://app.cochat.ai/papers/10.1002/biot.201200386
- The paper
- Kumar, S., Kumar, S., Ali, M. A., Anand, P., Agrawal, V. V., John, R., Maji, S., & Malhotra, B. D. (2013). Microfluidic‐integrated biosensors: Prospects for point‐of‐care diagnostics. Biotechnology Journal. https://doi.org/10.1002/biot.201200386
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.