The DOI matches its Crossref record.
Ellipsometry as a tool to study the adsorption behavior of synthetic and biopolymers at the air–water interface
Abstract
The application of ellipsometry of the study of the adsorption behavior of proteins and synthetic macromolecules at the air‐water interface has been investigated. It is shown that for macromolecules the amount adsorbed per unit area, Γ, as determined by ellipsometry, only has a well‐defined physical meaning if the refractive‐index increment remains constant up to high concentrations present in the adsorbed layer. It has been found experimentally that this conditioned is fulfilled for proteins. The ellipsometric Γ values of some protein agree satisfactorily with those obtained by two independent techniques has been used to investigate the adsorption from solution of κ‐casein, bovine serum albumin, and polyvinyl alcohol. For bovine serum albumin, Γ reaches a plateau value of 2.9 mg/m 2 for concentrations ≥ 0.05 wt%. The thickness of the adsorbed molecules. For κ‐casein, Γ steadily increases with increasing centration and multilayers are formed. The technique provides interesting information on conformational changes in adsorbed macromolecules, on the rate of the process, and on the conditions under which these occur.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Electrochemical Biosensors - Sensor Principles and Architectures
Grieshaber, D., MacKenzie, R., Vörös, J., & Reimhult, E. (2008) · Sensors · doi:10.3390/s80314000 · Cited by 2,329
Protein Resistance of Titanium Oxide Surfaces Modified by Biologically Inspired mPEG−DOPA
Dalsin, J. L., Lin, L., Tosatti, S., Vörös, J., Textor, M., & Messersmith, P. B. (2005) · Langmuir · doi:10.1021/la048626g · Cited by 455
Effect of Chain Density on Inhibition of Protein Adsorption by Poly(ethylene glycol) Based Coatings
Malmsten, M., Emoto, K., & Van Alstine, J. M. (1998) · Journal of Colloid and Interface Science · doi:10.1006/jcis.1998.5513 · Cited by 342
Integrated planar optical waveguide interferometer biosensors: A comparative review
Kozma, P., Kehl, F., Ehrentreich-Förster, E., Stamm, C., & Bier, F. F. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.02.049 · Cited by 324
Competitive adsorption of collagen and bovine serum albumin—effect of the surface wettability
Ying, P., Jin, G., & Tao, Z. (2004) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/j.colsurfb.2003.10.015 · Cited by 62
Metadata
- Authors
- De Feijter, J. A., Benjamins, J., & Veer, F. A.
- Venue
- Biopolymers
- Publisher
- Wiley
- Published
- 1978-07
- Volume
- 17
- Issue
- 7
- Pages
- 1759-1772
- ISSN
- 0006-3525 (ISSN-L)
- 1097-0282
- OpenAlex
- W2155963087
- Cited by
- 1,289
- References
- 0
- FWCI
- 1.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ellipsometry as a tool to study the adsorption behavior of synthetic and biopolymers at the air–water interface. https://app.cochat.ai/papers/10.1002/bip.1978.360170711
- The paper
- De Feijter, J. A., Benjamins, J., & Veer, F. A. (1978). Ellipsometry as a tool to study the adsorption behavior of synthetic and biopolymers at the air–water interface. Biopolymers. https://doi.org/10.1002/bip.1978.360170711
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.