The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Stabilization of α‐chymotrypsin by ionic liquids in transesterification reactions
Abstract
Five different ionic liquids, based on dialkylimidazolium and quaternary ammonium cations associated with perfluorinated and bis (trifluoromethyl) sulfonyl amide anions, were used as reaction media to synthesize N‐acetyl‐L‐tyrosine propyl ester by transesterification with α‐chymotrypsin at 2% (v/v) water content at 50°C. The synthetic activity was reduced by the increase in alkyl chains length of cations and by increases in anion size, which was related to the decrease in polarity. Incubation of the enzyme (with and without substrate) in ionic liquids exhibited first‐order deactivation kinetics at 50°C, allowing determination of deactivation rate constants and half‐life times (1–3 h). Ionic liquids showed a clear relative stabilization effect on the enzyme, which was improved by increased chain length of the alkyl substituents on the imidazolium ring cations and the anion size. This effect was 10‐times enhanced by the presence of substrate. For example, 1‐butyl‐3‐methylimidazolium hexafluorophosphate increased the α‐chymotrypsin half‐life by 200 times in the presence of substrate with respect to the 1‐propanol medium. These results show that ionic liquids are excellent enzyme‐stabilizing agents and reaction media for clean biocatalysis in non‐conventional conditions. © 2001 John Wiley & Sons, Inc. Biotechnol Bioeng 75: 563–569, 2001.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Air and water stable 1-ethyl-3-methylimidazolium based ionic liquids
Wilkes, J. S., & Zaworotko, M. J. (1992) · Journal of the Chemical Society, Chemical Communications · doi:10.1039/c39920000965 · Cited by 1,883
Cited by
van Rantwijk, F., & Sheldon, R. A. (2007) · Chemical Reviews · doi:10.1021/cr050946x · Cited by 1,561
Chemical and biochemical transformations in ionic liquids
Jain, N., Kumar, A., Chauhan, S., & Chauhan, S. M. S. (2005) · Tetrahedron · doi:10.1016/j.tet.2004.10.070 · Cited by 726
Applications of ionic liquids in electrochemical sensors
Wei, D., & Ivaska, A. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2007.12.011 · Cited by 714
Ionic liquids: Green solvents for nonaqueous biocatalysis
Yang, Z., & Pan, W. (2005) · Enzyme and Microbial Technology · doi:10.1016/j.enzmictec.2005.02.014 · Cited by 672
Biocatalysis in ionic liquids – advantages beyond green technology
Park, S., & Kazlauskas, R. J. (2003) · Current Opinion in Biotechnology · doi:10.1016/s0958-1669(03)00100-9 · Cited by 651
Metadata
- Authors
- Lozano, P., de Diego, T., Guegan, J., Vaultier, M., & Iborra, J. L.
- Venue
- Biotechnology and Bioengineering
- Publisher
- Wiley
- Published
- 2001-10-22
- Volume
- 75
- Issue
- 5
- Pages
- 563-569
- ISSN
- 0006-3592 (ISSN-L)
- 1097-0290
- OpenAlex
- W2171398954
- Cited by
- 229
- References
- 1
- FWCI
- 2.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Stabilization of α‐chymotrypsin by ionic liquids in transesterification reactions. https://app.cochat.ai/papers/10.1002/bit.10089
- The paper
- Lozano, P., de Diego, T., Guegan, J., Vaultier, M., & Iborra, J. L. (2001). Stabilization of α‐chymotrypsin by ionic liquids in transesterification reactions. Biotechnology and Bioengineering. https://doi.org/10.1002/bit.10089
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.