CoChat

The response of GS‐NS0 myeloma cells to single and multiple pH perturbations

Osman, Jason J., Birch, John, Varley, Julie · 2002 · Biotechnology and Bioengineering
Cited by 62

The DOI matches its Crossref record.

Abstract

Animal cells are cultured in several types of vessels at laboratory and industrial scale the most common being the stirred tank and the air‐lift. Economically, it is preferable to culture animal cells at the largest possible scale but the perceived sensitivity of animal cells to hydrodynamic shear has, until now, limited the aeration and agitation rates used. This has been reported to cause inhomogeneities in operational parameters such as dissolved oxygen concentration, temperature and pH. pH is of special interest during the latter stages of many animal cell fermentation because alkali additions, used for pH control, can cause large local pH perturbations of varying size and duration. The effect of single and multiple pH perturbations on the cell growth of a widely used GS‐NS0 mouse myeloma cell line grown in batch culture was investigated. The effect of perturbation amplitude and duration was investigated using a single stirred tank reactor (STR). In the single STR system cells were subjected to one pH 8.0 or 9.0 perturbation ranging in duration from 0–90 minutes. No measurable decrease in viable cell number was seen for pH 8.0 perturbations of any duration whereas pH 9.0 perturbations lasting for 10 minutes caused a 15% decrease in viable cell number. The proportion of viable cells decreased with increasing perturbation time and a 90‐minute exposure killed all of the cells. The effect of multiple pH perturbations on GS‐NS0 cells was investigated using two connected STR's. More specifically the number of perturbations and the perturbation frequency were investigated. Cells were subjected to between 0 and 100 perturbations at pH 8.0; the time between each perturbation (frequency) was 6 minutes and each perturbation lasted for 200 seconds. Viable cell number decreased with increasing perturbation number, with 100 perturbations causing death of 27.5% of cells. Cells were also exposed to 10 perturbations at pH 9.0, each of 200 second duration at frequencies of either 6, 18 or 60 minutes. Approximately 8 times more cells were killed with perturbations at a 6‐minute frequency (28.3% cell death) than at a 60‐minute frequency (3.4% cell death). © 2002 Wiley Periodicals, Inc. Biotechnol Bioeng 79: 398–407, 2002.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/bit.10198

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Osman, J. J., Birch, J., & Varley, J.
Venue
Biotechnology and Bioengineering
Publisher
Wiley
Published
2002-06-12
Volume
79
Issue
4
Pages
398-407
ISSN
  • 0006-3592 (ISSN-L)
  • 1097-0290
OpenAlex
W2161270865
Cited by
62
References
0
FWCI
1.44
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.