Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 238

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Determination of oxygen gradients in engineered tissue using a fluorescent sensor

Open access
Kellner, Karin, Liebsch, Gregor, Klimant, Ingo, Wolfbeis, Otto S., Blunk, Torsten, Schulz, Michaela B., Göpferich, Achim·2002·Biotechnology and Bioengineering

Abstract

Nutrient and oxygen supply of cells are crucial to tissue engineering in general. If a sufficient supply cannot be maintained, the development of the tissue will slow down or even fail completely. Previous studies on oxygen supply have focused on measurement of oxygen partial pressures (pO 2) in culture media or described the use of invasive techniques with spatially limited resolution. The experimental setup described here allows for continuous, noninvasive, high‐resolution pO 2 measurements over the cross‐section of cultivated tissues. Applying a recently developed technique for time‐resolved pO 2 sensing using optical sensor foils, containing luminescent O 2‐sensitive indicator dyes, we were able to monitor and analyze gradients in the oxygen supply in a tissue over a 3‐week culture period. Cylindrical tissue samples were immobilized on top of the sensors. By measuring the luminescence decay time, two‐dimensional pO 2 distributions across the tissue section in contact with the foil surface were determined. We applied this technique to cartilage explants and to tissue‐engineered cartilage. For both tissue types, changes were detected in monotonously decreasing gradients of pO 2 from the surface with high pO 2 to minimum pO 2 values in the center of the samples. Nearly anoxic conditions were observed in tissue constructs (∼0 Torr) but not in excised cartilage discs (∼20 Torr) after 1 day. Furthermore, the oxygen supply seemed to strongly depend on cell density and cell function. Additionally, histological analysis revealed a maximum depth of ∼1.3 mm of regular cartilage development in constructs grown under the applied culture conditions. Correlating analytical and histological analysis with the oxygen distributions, we found that pO 2 values below 11 Torr might impair proper tissue development in the center. The results illustrate that the method developed is an ideal one to precisely assess the oxygen demand of cartilage cultures. © 2002 Wiley Periodicals, Inc. Biotechnol Bioeng 80: 73–83, 2002.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/bit.10352

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 238

Metadata

Authors
Kellner, K., Liebsch, G., Klimant, I., Wolfbeis, O. S., Blunk, T., Schulz, M. B., & Göpferich, A.
Venue
Biotechnology and Bioengineering
Publisher
Wiley
Published
2002-08-09
Volume
80
Issue
1
Pages
73-83
ISSN
  • 0006-3592 (ISSN-L)
  • 1097-0290
OpenAlex
W2091415443
Cited by
238
References
1
FWCI
10.59
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.