The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Anisotropic stretch‐induced hypertrophy in neonatal ventricular myocytes micropatterned on deformable elastomers
Abstract
Because cell shape and alignment, cell–matrix adhesion, and cell–cell contact can all affect growth, and because mechanical strains in vivo are multiaxial and anisotropic, we developed an in vitro system for engineering aligned, rod‐shaped, neonatal cardiac myocyte cultures. Photolithographic and microfluidic techniques were used to micropattern extracellular matrices in parallel lines on deformable silicone elastomers. Confluent, elongated, aligned myocytes were produced by varying the micropattern line width and collagen density. An elliptical cell stretcher applied 2:1 anisotropic strain statically to the elastic substrate, with the axis of greatest stretch (10%) either parallel or transverse to the myofibrils. After 24 h, the principal strain parallel to myocytes did not significantly alter myofibril accumulation or expression of atrial natriuretic factor (ANF), connexin‐43 (Cx‐43), or N‐cadherin (by indirect immunofluorescent antibody labeling and immunoblotting) compared with unstretched controls. In contrast, 10% transverse principal strain resulted in continuous staining of actin filaments (rhodamine phalloidin); increased immunofluorescent labeling of ANF, Cx‐43, and N‐cadherin; and upregulation of protein signal intensity by western blotting. By using microfabrication and microfluidics to control cell shape and alignment on an elastic substrate, we found greater effects for transverse than for longitudinal stretch in regulating sarcomere organization, hypertrophy, and cell‐to‐cell junctions. © 2003 Wiley Periodicals, Inc. Biotechnol Bioeng 81: 578–587, 2003.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bhatia, S. N., Balis, U. J., Yarmush, M. L., & Toner, M. (1999) · The FASEB Journal · doi:10.1096/fasebj.13.14.1883 · Cited by 890
Self-citation
Cited by
Bhatia, S. N., & Ingber, D. E. (2014) · Nature Biotechnology · doi:10.1038/nbt.2989 · Cited by 3,305
Self-citationStructural and functional characterisation of cardiac fibroblasts
CAMELLITI, P., BORG, T., & KOHL, P. (2005) · Cardiovascular Research · doi:10.1016/j.cardiores.2004.08.020 · Cited by 930
Nanoscale cues regulate the structure and function of macroscopic cardiac tissue constructs
Kim, D.-H., Lipke, E. A., Kim, P., Cheong, R., Thompson, S., Delannoy, M., Suh, K.-Y., Tung, L., & Levchenko, A. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0906504107 · Cited by 611
Modular tissue engineering: engineering biological tissues from the bottom up
Nichol, J. W., & Khademhosseini, A. (2009) · Soft Matter · doi:10.1039/b814285h · Cited by 567
Substrate Stiffness Affects the Functional Maturation of Neonatal Rat Ventricular Myocytes
Jacot, J. G., McCulloch, A. D., & Omens, J. H. (2008) · Biophysical Journal · doi:10.1529/biophysj.107.124545 · Cited by 448
Self-citation
Metadata
- Authors
- Gopalan, S. M., Flaim, C., Bhatia, S. N., Hoshijima, M., Knoell, R., Chien, K. R., Omens, J. H., & McCulloch, A. D.
- Venue
- Biotechnology and Bioengineering
- Publisher
- Wiley
- Published
- 2002-12-23
- Volume
- 81
- Issue
- 5
- Pages
- 578-587
- ISSN
- 0006-3592 (ISSN-L)
- 1097-0290
- OpenAlex
- W2117445552
- Cited by
- 183
- References
- 1
- FWCI
- 2.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Anisotropic stretch‐induced hypertrophy in neonatal ventricular myocytes micropatterned on deformable elastomers. https://app.cochat.ai/papers/10.1002/bit.10506
- The paper
- Gopalan, S. M., Flaim, C., Bhatia, S. N., Hoshijima, M., Knoell, R., Chien, K. R., Omens, J. H., & McCulloch, A. D. (2003). Anisotropic stretch‐induced hypertrophy in neonatal ventricular myocytes micropatterned on deformable elastomers. Biotechnology and Bioengineering. https://doi.org/10.1002/bit.10506
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.