The DOI matches its Crossref record.
Integrated optical sensing of dissolved oxygen in microtiter plates: A novel tool for microbial cultivation
Abstract
Microtiter plates with integrated optical sensing of dissolved oxygen were developed by immobilization of two fluorophores at the bottom of 96‐well polystyrene microtiter plates. The oxygen‐sensitive fluorophore responded to dissolved oxygen concentration, whereas the oxygen‐insensitive one served as an internal reference. The sensor measured dissolved oxygen accurately in optically well‐defined media. Oxygen transfer coefficients, k L a, were determined by a dynamic method in a commercial microtiter plate reader with an integrated shaker. For this purpose, the dissolved oxygen was initially depleted by the addition of sodium dithionite and, by oxygen transfer from air, it increased again after complete oxidation of dithionite. k L a values in one commercial reader were about 10 to 40 h−1. k L a values were inversely proportional to the filling volume and increased with increasing shaking intensity. Dissolved oxygen was monitored during cultivation of Corynebacterium glutamicum in another reader that allowed much higher shaking intensity. Growth rates determined from optical density measurement were identical to those observed in shaking flasks and in a stirred fermentor. Oxygen uptake rates measured in the stirred fermentor and dissolved oxygen concentrations measured during cultivation in the microtiter plate were used to estimate k L a values in a 96‐well microtiter plate. The resulting values were about 130 h−1, which is in the lower range of typical stirred fermentors. The resulting maximum oxygen transfer rate was 26 m M h−1. Simulations showed that the errors caused by the intermittent measurement method were insignificant under the prevailing conditions. © 2003 Wiley Periodicals, Inc. Biotechnol Bioeng 81: 829–836, 2003.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Optical methods for sensing and imaging oxygen: materials, spectroscopies and applications
Wang, X.-D., & Wolfbeis, O. S. (2014) · Chem. Soc. Rev. · doi:10.1039/c4cs00039k · Cited by 1,114
Indicators for optical oxygen sensors
Quaranta, M., Borisov, S. M., & Klimant, I. (2012) · Bioanalytical Reviews · doi:10.1007/s12566-012-0032-y · Cited by 452
Self-citationHypoxia in Static and Dynamic 3D Culture Systems for Tissue Engineering of Bone
Volkmer, E., Drosse, I., Otto, S., Stangelmayer, A., Stengele, M., Kallukalam, B. C., Mutschler, W., & Schieker, M. (2008) · Tissue Engineering Part A · doi:10.1089/ten.tea.2007.0231 · Cited by 285
Kensy, F., Zang, E., Faulhammer, C., Tan, R.-K., & Büchs, J. (2009) · Microbial Cell Factories · doi:10.1186/1475-2859-8-31 · Cited by 253
Rivera, K. R., Yokus, M. A., Erb, P. D., Pozdin, V. A., & Daniele, M. (2019) · The Analyst · doi:10.1039/c8an02201a · Cited by 57
Metadata
- Authors
- John, G. T., Klimant, I., Wittmann, C., & Heinzle, E.
- Venue
- Biotechnology and Bioengineering
- Publisher
- Wiley
- Published
- 2003-01-16
- Volume
- 81
- Issue
- 7
- Pages
- 829-836
- ISSN
- 0006-3592 (ISSN-L)
- 1097-0290
- OpenAlex
- W2103158467
- Cited by
- 199
- References
- 0
- FWCI
- 14.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.