The DOI matches its Crossref record.
Oxygen gradients in tissue‐engineered Pegt/Pbt cartilaginous constructs: Measurement and modeling
Open accessAbstract
The supply of oxygen within three‐dimensional tissue‐engineered (TE) cartilage polymer constructs is mainly by diffusion. Oxygen consumption by cells results in gradients in the oxygen concentration. The aims of this study were, firstly, to identify the gradients within TE cartilage polymer constructs and, secondly, to predict the profiles during in vitro culture. A glass microelectrode system was adapted and used to penetrate cartilage and TE cartilaginous constructs, yielding reproducible measurements with high spatial resolution. Cartilage polymer constructs were cultured for up to 41 days in vitro. Oxygen concentrations, as low as 2–5%, were measured within the center of these constructs. At the beginning of in vitro culture, the oxygen gradients were steeper in TE constructs in comparison to native tissue. Nevertheless, during the course of culture, oxygen concentrations approached the values measured in native tissue. A mathematical model was developed which yields oxygen profiles within cartilage explants and TE constructs. Model input parameters were assessed, including the diffusion coefficient of cartilage (2.2 × 10−9) + (0.4 × 10−9 m 2 s−1), 70% of the diffusion coefficient of water and the diffusion coefficient of constructs (3.8 × 10−10 m 2 s−1). The model confirmed that chondrocytes in polymer constructs cultured for 27 days have low oxygen requirements (0.8 × 10−19 mol m−3 s−1), even lower than chondrocytes in native cartilage. The ability to measure and predict local oxygen tensions offers new opportunities to obtain more insight in the relation between oxygen tension and chondrogenesis. © 2004 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Recent advances in bone tissue engineering scaffolds
Bose, S., Roy, M., & Bandyopadhyay, A. (2012) · Trends in Biotechnology · doi:10.1016/j.tibtech.2012.07.005 · Cited by 2,206
Vascularization in tissue engineering
Rouwkema, J., Rivron, N. C., & van Blitterswijk, C. A. (2008) · Trends in Biotechnology · doi:10.1016/j.tibtech.2008.04.009 · Cited by 1,211
Self-citationVascularization Strategies for Tissue Engineering
Lovett, M., Lee, K., Edwards, A., & Kaplan, D. L. (2009) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2009.0085 · Cited by 923
Electrospinning for tissue engineering applications
Rahmati, M., Mills, D. K., Urbanska, A. M., Saeb, M. R., Venugopal, J. R., Ramakrishna, S., & Mozafari, M. (2021) · Progress in Materials Science · doi:10.1016/j.pmatsci.2020.100721 · Cited by 816
Bioactive polymeric scaffolds for tissue engineering
Stratton, S., Shelke, N. B., Hoshino, K., Rudraiah, S., & Kumbar, S. G. (2016) · Bioactive Materials · doi:10.1016/j.bioactmat.2016.11.001 · Cited by 469
Metadata
- Authors
- Malda, J., Rouwkema, J., Martens, D. E., le Comte, E. P., Kooy, F. K., Tramper, J., van Blitterswijk, C. A., & Riesle, J.
- Venue
- Biotechnology and Bioengineering
- Publisher
- Wiley
- Published
- 2004-02-12
- Volume
- 86
- Issue
- 1
- Pages
- 9-18
- ISSN
- 0006-3592 (ISSN-L)
- 1097-0290
- OpenAlex
- W2158107118
- Cited by
- 325
- References
- 0
- FWCI
- 12.42
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Oxygen gradients in tissue‐engineered Pegt/Pbt cartilaginous constructs: Measurement and modeling. https://app.cochat.ai/papers/10.1002/bit.20038
- The paper
- Malda, J., Rouwkema, J., Martens, D. E., le Comte, E. P., Kooy, F. K., Tramper, J., van Blitterswijk, C. A., & Riesle, J. (2004). Oxygen gradients in tissue‐engineered Pegt/Pbt cartilaginous constructs: Measurement and modeling. Biotechnology and Bioengineering. https://doi.org/10.1002/bit.20038
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.