A stirred microchamber for oxygen consumption rate measurements with pancreatic islets
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Improvements in pancreatic islet transplantation for treatment of diabetes are hindered by the absence of meaningful islet quality assessment methods. Oxygen consumption rate (OCR) has previously been used to assess the quality of organs and primary tissue for transplantation. In this study, we describe and characterize a stirred microchamber for measuring OCR with small quantities of islets. The device has a titanium body with a chamber volume of about 200 µL and is magnetically stirred and water jacketed for temperature control. Oxygen partial pressure (pO 2) is measured by fluorescence quenching with a fiber optic probe, and OCR is determined from the linear decrease of pO 2 with time. We demonstrate that measurements can be made rapidly and with high precision. Measurements with βTC3 cells and islets show that OCR is directly proportional to the number of viable cells in mixtures of live and dead cells and correlate linearly with membrane integrity measurements made with cells that have been cultured for 24 h under various stressful conditions. Biotechnol. Bioeng. 2007;98: 1071–1082. © 2007 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Shapiro, A. M. J., Lakey, J. R. T., Ryan, E. A., Korbutt, G. S., Toth, E., Warnock, G. L., Kneteman, N. M., & Rajotte, R. V. (2000) · New England Journal of Medicine · doi:10.1056/nejm200007273430401 · Cited by 5,237
Cell Loss in Isolated Human Islets Occurs by Apoptosis
Paraskevas, S., Maysinger, D., Wang, R., Duguid, W. P., & Rosenberg, L. (2000) · Pancreas · doi:10.1097/00006676-200004000-00008 · Cited by 229 · cited 2×
“, 2003) and are exposed to periods of warm and cold ischemia (Papas et al., 2005; Paraskevas et al., 2000).”
Background
Cited by
Enhanced Oxygen Supply Improves Islet Viability in a New Bioartificial Pancreas
Barkai, U., Weir, G. C., Colton, C. K., Ludwig, B., Bornstein, S. R., Brendel, M. D., Neufeld, T., Bremer, C., Leon, A., Evron, Y., et al. (2013) · Cell Transplantation · doi:10.3727/096368912x657341 · Cited by 193
Self-citationFEM-based oxygen consumption and cell viability models for avascular pancreatic islets
Buchwald, P. (2009) · Theoretical Biology and Medical Modelling · doi:10.1186/1742-4682-6-5 · Cited by 187
Ludwig, B., Rotem, A., Schmid, J., Weir, G. C., Colton, C. K., Brendel, M. D., Neufeld, T., Block, N. L., Yavriyants, K., Steffen, A., et al. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1201868109 · Cited by 177
Self-citationOxygen supply to encapsulated therapeutic cells
Colton, C. K. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2014.02.007 · Cited by 162
Self-citationPepper, A. R., Pawlick, R., Bruni, A., Wink, J., Rafiei, Y., O’Gorman, D., Yan-Do, R., Gala-Lopez, B., Kin, T., MacDonald, P. E., et al. (2017) · Stem Cell Reports · doi:10.1016/j.stemcr.2017.05.004 · Cited by 96
Metadata
- Authors
- Papas, K. K., Pisania, A., Wu, H., Weir, G. C., & Colton, C. K.
- Venue
- Biotechnology and Bioengineering
- Publisher
- Wiley
- Published
- 2007-05-11
- Volume
- 98
- Issue
- 5
- Pages
- 1071-1082
- ISSN
- 0006-3592 (ISSN-L)
- 1097-0290
- OpenAlex
- W2111347785
- Cited by
- 105
- References
- 2
- FWCI
- 6.42
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A stirred microchamber for oxygen consumption rate measurements with pancreatic islets. https://app.cochat.ai/papers/10.1002/bit.21486
- The paper
- Papas, K. K., Pisania, A., Wu, H., Weir, G. C., & Colton, C. K. (2007). A stirred microchamber for oxygen consumption rate measurements with pancreatic islets. Biotechnology and Bioengineering. https://doi.org/10.1002/bit.21486
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.