CoChat

Accelerated cell line development using two‐color fluorescence activated cell sorting to select highly expressing antibody‐producing clones

Sleiman, Robert J., Gray, Peter P., McCall, Martin N., Codamo, Joe, Sunstrom, Noelle‐Ann S. · 2008 · Biotechnology and Bioengineering
Cited by 70

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

The success of engineered monoclonal antibodies as biopharmaceuticals has generated considerable interest in strategies designed to accelerate development of antibody expressing cell lines. Stable mammalian cell lines that express therapeutic antibodies at high levels typically take 6–12 months to develop. Here we describe a novel method to accelerate selection of cells expressing recombinant proteins (e.g., antibodies) using multiparameter fluorescence activated cell sorting (FACS) in association with dual intracellular autofluorescent reporter proteins. The method is co‐factor‐independent and does not require complex sample preparation. Chinese hamster ovary (CHO) clones expressing high levels of recombinant antibody were selected on the basis of a two‐color FACS sorting strategy using heavy and light chain‐specific fluorescent reporter proteins. We were able to establish within 12 weeks of transfection cell lines with greater than a 38‐fold increase in antibody production when compared to the pool from which they were isolated, following a single round of FACS. The method provides a robust strategy to accelerate selection and characterization of clones and builds a foundation for a predictive model of specific productivity based upon on two‐color fluorescence. Biotechnol. Bioeng. 2008;99: 578–587. © 2007 Wiley Periodicals, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/bit.21612

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 70

Metadata

Authors
Sleiman, R. J., Gray, P. P., McCall, M. N., Codamo, J., & Sunstrom, N. S.
Venue
Biotechnology and Bioengineering
Publisher
Wiley
Published
2007-08-06
Volume
99
Issue
3
Pages
578-587
ISSN
  • 0006-3592 (ISSN-L)
  • 1097-0290
OpenAlex
W2128723663
Cited by
70
References
2
FWCI
1.80
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Accelerated cell line development using two‐color fluorescence activated cell sorting to select highly expressing antibody‐producing clones. https://app.cochat.ai/papers/10.1002/bit.21612
The paper
Sleiman, R. J., Gray, P. P., McCall, M. N., Codamo, J., & Sunstrom, N. S. (2008). Accelerated cell line development using two‐color fluorescence activated cell sorting to select highly expressing antibody‐producing clones. Biotechnology and Bioengineering. https://doi.org/10.1002/bit.21612

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.