CoChat

The baffled microtiter plate: Increased oxygen transfer and improved online monitoring in small scale fermentations

Funke, Matthias, Diederichs, Sylvia, Kensy, Frank, Müller, Carsten, Büchs, Jochen · 2009 · Biotechnology and Bioengineering
Cited by 148

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Most experiments in screening and process development are performed in shaken bioreactors. Today, microtiter plates are the preferred vessels for small‐scale microbial cultivations in high throughput, even though they have never been optimized for this purpose. To interpret the experimental results correctly and to obtain a base for a meaningful scale‐up, sufficient oxygen supply to the culture liquid is crucial. For shaken bioreactors this problem can generally be addressed by the introduction of baffles. Therefore, the focus of this study is to investigate how baffling and the well geometry affect the maximum oxygen transfer capacity (OTR max) in microtiter plates. On a 48‐well plate scale, 30 different cross‐section geometries of a well were studied. It could be shown that the introduction of baffles into the common circular cylinder of a microtiter plate well doubles the maximum oxygen transfer capacity, resulting in values above 100 mmol/L/h (kLa > 600 1/h). To also guarantee a high volume for microbial cultivation, it is important to maximize the filling volume, applicable during orbital shaking. Additionally, the liquid height at the well bottom was examined, which is a decisive parameter for online‐monitoring systems such as the BioLector. This technology performs fiber‐optical measurements through the well bottom, therefore requires a constant liquid height at all shaking frequencies. Ultimately, a six‐petal flower‐shaped well geometry was shown to be the optimal solution taking into account all aforementioned criteria. With its favorable culture conditions and the possibility for unrestricted online monitoring, this novel microtiter plate is an efficient tool to gain meaningful results for interpreting and scaling‐up experiments in clone screening and bioprocess development. Biotechnol. Bioeng. 2009;103: 1118–1128. © 2009 Wiley Periodicals, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/bit.22341

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 148

Metadata

Authors
Funke, M., Diederichs, S., Kensy, F., Müller, C., & Büchs, J.
Venue
Biotechnology and Bioengineering
Publisher
Wiley
Published
2009-05-15
Volume
103
Issue
6
Pages
1118-1128
ISSN
  • 0006-3592 (ISSN-L)
  • 1097-0290
OpenAlex
W1975747950
Cited by
148
References
1
FWCI
4.66
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.