Microwell engineering characterization for mammalian cell culture process development
The DOI matches its Crossref record.
Abstract
Experimentation in shaken microplate formats offers a potential platform technology for the rapid evaluation and optimization of cell culture conditions. Provided that cell growth and antibody production kinetics are comparable to those found in currently used shake flask systems then the microwell approach offers the possibility to obtain early process design data more cost effectively and with reduced material requirements. This work describes a detailed engineering characterization of liquid mixing and gas–liquid mass transfer in microwell systems and their impact on suspension cell cultures. For growth of murine hybridoma cells producing IgG1, 24‐well plates have been characterized in terms of energy dissipation (P/V) (via Computational Fluid Dynamics, CFD), fluid flow, mixing and oxygen transfer rate as a function of shaking frequency and liquid fill volume. Predicted kLa values varied between 1.3 and 29 h−1; liquid‐phase mixing time, quantified using iodine decolorization experiments, varied from 1.7 s to 3.5 h; while the predicted P/V ranged from 5 to 35 W m−3. CFD simulations of the shear rate predicted hydrodynamic forces will not be detrimental to cells. For hybridoma cultures however, high shaking speeds (>250 rpm) were shown to have a negative impact on cell growth, while a combination of low shaking speed and high well fill volume (120 rpm, 2,000 µL) resulted in oxygen limited conditions. Based on these findings a first engineering comparison of cell culture kinetics in microwell and shake flask formats was made at matched average energy dissipation rates. Cell growth kinetics and antibody titer were found to be similar in 24‐well microtiter plates and 250 mL shake flasks. Overall this work has demonstrated that cell culture performed in shaken microwell plates can provide data that is both reproducible and comparable to currently used shake flask systems while offering at least a 30‐fold decrease in scale of operation and material requirements. Linked with automation this provides a route towards the high throughput evaluation of robust cell lines under realistic suspension culture conditions. Biotechnol. Bioeng. 2010; 105: 260–275. © 2009 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Perfusion mammalian cell culture for recombinant protein manufacturing – A critical review
Bielser, J.-M., Wolf, M., Souquet, J., Broly, H., & Morbidelli, M. (2018) · Biotechnology Advances · doi:10.1016/j.biotechadv.2018.04.011 · Cited by 263
Ojo, E. O., Auta, H., Baganz, F., & Lye, G. J. (2015) · Biochemical Engineering Journal · doi:10.1016/j.bej.2015.07.006 · Cited by 26
Self-citationLaboratory-scale photobiotechnology—current trends and future perspectives
Morschett, H., Loomba, V., Huber, G., Wiechert, W., von Lieres, E., & Oldiges, M. (2018) · FEMS Microbiology Letters · doi:10.1093/femsle/fnx238 · Cited by 14
Lucas, C., Blackman, M., Rayat, A., Mainwaring, D., & Micheletti, M. (2024) · Journal of Advanced Manufacturing and Processing · doi:10.1002/amp2.10180 · Cited by 4
Metadata
- Authors
- Barrett, T. A., Wu, A., Zhang, H., Levy, M. S., & Lye, G. J.
- Venue
- Biotechnology and Bioengineering
- Publisher
- Wiley
- Published
- 2009-10-21
- Volume
- 105
- Issue
- 2
- Pages
- 260-275
- ISSN
- 0006-3592 (ISSN-L)
- 1097-0290
- OpenAlex
- W2131417207
- Cited by
- 98
- References
- 0
- FWCI
- 3.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.