The DOI matches its Crossref record.
Investigation of the mesoscale structure and volumetric features of biofilms using optical coherence tomography
Abstract
Optical coherence tomography (OCT) was successfully applied to visualize the mesoscale structure of three different heterotrophic biofilms. For this purpose, biofilm volumes of 4 × 4 × 1.6 mm 3 were scanned with spatial resolutions lower than 20 µm within an acquisition time of 2 min. A heterogeneous structure was detected for biofilms cultivated in laminar as well as transient flow conditions. The structure was found to be more homogeneous for the biofilm grown in turbulent flow. This biofilm structure was characterized by a volumetric porosity of 0.36, whereas the porosity calculated for biofilms grown in laminar and transient conditions was 0.65. These results were directly generated from the distribution of porosity calculated from the OCT images acquired and can be linked to structural properties. Up to now, the mesoscale biofilm structure was only observable with time‐consuming and expensive studies, for example, magnetic resonance microscopy. OCT will most certainly be helpful for improved understanding and prediction of biofilm physics with respect to macroscale processes, for example, mass transfer and detachment as the information about mesoscale is easily accessible using this method. In the context of this study, we show that CLSM images do not necessarily provide an accurate representation of the biofilm structure at the mesoscale. Additionally, the typical characteristic parameters obtained from CLSM image stacks differ largely from those calculated from OCT images. Nevertheless, to determine the local distribution of biofilm constituents, microscopic methods such as confocal laser scanning microscopy are required. Biotechnol. Bioeng. 2010;107: 844–853. © 2010 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Gravity-driven membrane filtration for water and wastewater treatment: A review
Pronk, W., Ding, A., Morgenroth, E., Derlon, N., Desmond, P., Burkhardt, M., Wu, B., & Fane, A. G. (2019) · Water Research · doi:10.1016/j.watres.2018.11.062 · Cited by 455
Viscoelasticity of biofilms and their recalcitrance to mechanical and chemical challenges
Peterson, B. W., He, Y., Ren, Y., Zerdoum, A., Libera, M. R., Sharma, P. K., van Winkelhoff, A.-J., Neut, D., Stoodley, P., van der Mei, H. C., et al. (2015) · FEMS Microbiology Reviews · doi:10.1093/femsre/fuu008 · Cited by 346
Biofilms as living catalysts in continuous chemical syntheses
Halan, B., Buehler, K., & Schmid, A. (2012) · Trends in Biotechnology · doi:10.1016/j.tibtech.2012.05.003 · Cited by 293
Hydrodynamics and surface properties influence biofilm proliferation
Krsmanovic, M., Biswas, D., Ali, H., Kumar, A., Ghosh, R., & Dickerson, A. K. (2021) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2020.102336 · Cited by 285
Methodological approaches for studying the microbial ecology of drinking water distribution systems
Douterelo, I., Boxall, J. B., Deines, P., Sekar, R., Fish, K. E., & Biggs, C. A. (2014) · Water Research · doi:10.1016/j.watres.2014.07.008 · Cited by 260
Metadata
- Authors
- Wagner, M., Taherzadeh, D., Haisch, C., & Horn, H.
- Venue
- Biotechnology and Bioengineering
- Publisher
- Wiley
- Published
- 2010-08-17
- Volume
- 107
- Issue
- 5
- Pages
- 844-853
- ISSN
- 0006-3592 (ISSN-L)
- 1097-0290
- OpenAlex
- W2167576954
- Cited by
- 172
- References
- 0
- FWCI
- 2.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Investigation of the mesoscale structure and volumetric features of biofilms using optical coherence tomography. https://app.cochat.ai/papers/10.1002/bit.22864
- The paper
- Wagner, M., Taherzadeh, D., Haisch, C., & Horn, H. (2010). Investigation of the mesoscale structure and volumetric features of biofilms using optical coherence tomography. Biotechnology and Bioengineering. https://doi.org/10.1002/bit.22864
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.