Host cell protein quantification by fourier transform mid infrared spectroscopy (FT‐MIR)
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Process development in up‐ and downstream processing requires enhanced, non‐time‐consuming, and non‐expensive monitoring techniques to track product purity, for example, the level of endotoxins, viral particles, and host cell proteins (HCPs). Currently, HCP amounts are measured by laborious and expensive HCP‐enzyme‐linked immunosorbent assay (ELISA) assays best suited for measuring HCP amounts in the low concentration regime. The measurement of higher HCP amounts using this method requires dilution steps, adding dilution errors to the measurement. In this work we evaluated the suitability of attenuated total reflection spectroscopy for HCP quantification in process development, using clarified cell culture fluid from monoclonal antibody producing Chinese hamster ovary‐cells after treatment with different polyelectrolytes for semi‐selective clarification. Forty undiluted samples were chosen for multivariate data analysis in the middle infrared range and predicted HCP‐values were in good agreement with results obtained by an ELISA‐assay, suggesting the suitability of this new method for HCP‐quantification. As this method is able to quantify HCP titers ranging from approximately at least 20,000–200,000 ng mL−1, it is suitable especially for monitoring of process development steps with higher HCP concentrations, omitting dilution errors associated with ELISA assays. Biotechnol. Bioeng. 2013; 110: 252–259. © 2012 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fourier Transform Infrared Spectrometry
Griffiths, P. R., & de Haseth, J. A. (2007) · doi:10.1002/047010631x · Cited by 3,052
Near Infrared Spectroscopy for Bioprocess Monitoring and Control: Current Status and Future Trends
Scarff, M., Arnold, S. A., Harvey, L. M., & McNeil, B. (2006) · Critical Reviews in Biotechnology · doi:10.1080/07388550500513677 · Cited by 124 · cited 1×
“Thereby we avoided the risk of colinearity of protein concentrations in the samples (Martens and Naes, 1989; Scarff et al., 2006;Warnes et al., 1996) and were able to cover a wide space of the calibration area (Isaksson and Naes, 1990).”
Background
Cited by
Feidl, F., Garbellini, S., Vogg, S., Sokolov, M., Souquet, J., Broly, H., Butté, A., & Morbidelli, M. (2019) · Biotechnology Progress · doi:10.1002/btpr.2847 · Cited by 59
Goldrick, S., Umprecht, A., Tang, A., Zakrzewski, R., Cheeks, M., Turner, R., Charles, A., Les, K., Hulley, M., Spencer, C., et al. (2020) · Processes · doi:10.3390/pr8091179 · Cited by 48
“with limited sensitivity [52], which does not allow for widespread use.”
Background
Metadata
- Authors
- Capito, F., Skudas, R., Kolmar, H., & Stanislawski, B.
- Venue
- Biotechnology and Bioengineering
- Publisher
- Wiley
- Published
- 2012-08-08
- Volume
- 110
- Issue
- 1
- Pages
- 252-259
- ISSN
- 0006-3592 (ISSN-L)
- 1097-0290
- OpenAlex
- W2042836962
- Cited by
- 39
- References
- 2
- FWCI
- 3.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Host cell protein quantification by fourier transform mid infrared spectroscopy (FT‐MIR). https://app.cochat.ai/papers/10.1002/bit.24611
- The paper
- Capito, F., Skudas, R., Kolmar, H., & Stanislawski, B. (2013). Host cell protein quantification by fourier transform mid infrared spectroscopy (FT‐MIR). Biotechnology and Bioengineering. https://doi.org/10.1002/bit.24611
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.