Abstract

Host cell proteins (HCPs) are among the process‐related impurities monitored during recombinant protein pharmaceutical process development. The challenges of HCP detection include (1) low levels of residual HCPs present in large excess of product protein, (2) the assay must measure a large number of different protein analytes, and (3) the population of HCP species may change during process development. Suitable methods for measuring process‐related impurities are needed to support process development, process validation, and control system testing. A multi‐analyte enzyme‐linked immunosorbent assay (ELISA) is the workhorse method for HCP testing due to its high throughput, sensitivity and selectivity. However, as the anti‐HCP antibodies, the critical reagents for HCP ELISA, do not comprehensively recognize all the HCP species, it is especially important to ensure that weak and non‐immunoreactive HCPs are not overlooked by the ELISA. In some cases limited amount of antibodies to HCP species or antigen excess causes dilution‐dependent non‐linearity with multi‐product HCP ELISA. In our experience, correct interpretation of assay data can lead to isolation and identification of co‐purifying HCP with the product in some cases. Moreover, even if the antibodies for a particular HCP are present in the reagent, the corresponding HCP may not be readily detected in the ELISA due to antibody/antigen binding conditions and availability of HCP epitopes. This report reviews the use of the HCP ELISA, discusses its limitations, and demonstrates the importance of orthogonal methods, including mass spectrometry, to complement the platform HCP ELISA for support of process development. In addition, risk and impact assessment for low‐level HCPs is also outlined, with consideration of clinical information. Biotechnol. Bioeng. 2014;111: 2367–2379. © 2014 Wiley Periodicals, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/bit.25327

Cites

30 of 30 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 30 references

Cited by

See all 188

Metadata

Authors
Zhu‐Shimoni, J., Yu, C., Nishihara, J., Wong, R. M., Gunawan, F., Lin, M., Krawitz, D., Liu, P., Sandoval, W., & Vanderlaan, M.
Venue
Biotechnology and Bioengineering
Publisher
Wiley
Published
2014-09-10
Volume
111
Issue
12
Pages
2367-2379
ISSN
  • 0006-3592 (ISSN-L)
  • 1097-0290
OpenAlex
W2161846584
Cited by
188
References
30
FWCI
4.38
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Host cell protein testing by ELISAs and the use of orthogonal methods. https://app.cochat.ai/papers/10.1002/bit.25327
The paper
Zhu‐Shimoni, J., Yu, C., Nishihara, J., Wong, R. M., Gunawan, F., Lin, M., Krawitz, D., Liu, P., Sandoval, W., & Vanderlaan, M. (2014). Host cell protein testing by ELISAs and the use of orthogonal methods. Biotechnology and Bioengineering. https://doi.org/10.1002/bit.25327

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.