The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Dynamic measurement of the volumetric oxygen transfer coefficient in fermentation systems
Abstract
A rapid and internally consistent technique has been developed to measure the volumetric oxygen transfer coefficient, kLa, in fermentation systems. The method consists of tracing the dissolved O 2 concentration of the fermentation broth during a short interruption of the aeration. The O 2 concentration trace thus obtained can be analyzed to determine the values of kLa. Additional experiments on prolonged O 2 starvation, carried out to find the limitation of the technique, suggest that O 2 uptake rate will vary if a prolonged (2–10 min.) O 2 starvation occurs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Oxygen Transfer in Submerged Fermentation
Hixson, A. W., & Gaden, E. (1950) · Industrial & Engineering Chemistry · doi:10.1021/ie50489a031 · Cited by 109
Oxygen‐absorption rate‐controlled feeding of substrate into aerobic microbial cultures
Hospodka, J. (1966) · Biotechnology and Bioengineering · doi:10.1002/bit.260080111 · Cited by 43
Cited by
Bioreactor scale-up and oxygen transfer rate in microbial processes: An overview
Garcia-Ochoa, F., & Gomez, E. (2009) · Biotechnology Advances · doi:10.1016/j.biotechadv.2008.10.006 · Cited by 1,504
Oxygen uptake rate in microbial processes: An overview
Garcia-Ochoa, F., Gomez, E., Santos, V. E., & Merchuk, J. C. (2010) · Biochemical Engineering Journal · doi:10.1016/j.bej.2010.01.011 · Cited by 511
Dynamic measurement of the volumetric oxygen transfer coefficient in fermentation systems
Bandyopadhyay, B., Humphrey, A. E., Taguchi, H., & Govind Rao, I. B. (2009) · Biotechnology and Bioengineering · doi:10.1002/bit.22566 · Cited by 294
Self-citationAcetone production with metabolically engineered strains of Acetobacterium woodii
Hoffmeister, S., Gerdom, M., Bengelsdorf, F. R., Linder, S., Flüchter, S., Öztürk, H., Blümke, W., May, A., Fischer, R.-J., Bahl, H., et al. (2016) · Metabolic Engineering · doi:10.1016/j.ymben.2016.03.001 · Cited by 139
Metadata
- Authors
- Bandyopadhyay, B., Humphrey, A. E., & Taguchi, H.
- Venue
- Biotechnology and Bioengineering
- Publisher
- Wiley
- Published
- 1967-10
- Volume
- 9
- Issue
- 4
- Pages
- 533-544
- ISSN
- 0006-3592 (ISSN-L)
- 1097-0290
- OpenAlex
- W4233217132
- Cited by
- 338
- References
- 2
- FWCI
- 4.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dynamic measurement of the volumetric oxygen transfer coefficient in fermentation systems. https://app.cochat.ai/papers/10.1002/bit.260090408
- The paper
- Bandyopadhyay, B., Humphrey, A. E., & Taguchi, H. (1967). Dynamic measurement of the volumetric oxygen transfer coefficient in fermentation systems. Biotechnology and Bioengineering. https://doi.org/10.1002/bit.260090408
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.