The DOI matches its Crossref record.
Microbial electrode BOD sensors
Abstract
Two different types of biochemical oxygen demand (BOD) sensors using microbial electrodes were prepared. First, a microbial electrode using the bacteria–collagen membrane and oxygen electrode was used for the determination of BOD. When the electrode was inserted in a sample solution containing glucose and glutamic acid (model waste water), the current of the electrode decreased markedly with time until a steady state was reached. A linear relationship was observed between the steady state current and the concentration of the standard solution containing glucose–glutamic acid or the BOD of the solution. The BOD of industrial waste waters can be estimated within 15 min by using the microbial electrode. No decrease in current output was observed over a ten day period. The reproducibility was determined using the same sample (10% of the standard solution) and was found to be 26.2 ± 2.0 μA (7.5% of the relative standard deviation). Next, a biofuel cell utilizing microbial electrode (immobilized Clostridium butyricum–platinum electrode) was applied to the estimation of the BOD of waste waters. The current of the biofuel cell was decreased markedly with time until a steady state was reached. The steady state current was in all cases attained within 30–40 min at 37°C. A linear relationship was obtained between the steady state current and BOD. The BOD of industrial waste waters can be estimated by using the biofuel cell. Relative error of the BOD estimation was within ±10%. The current output of the biofuel cell was almost constant for 30 days.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Construction and operation of a novel mediator- and membrane-less microbial fuel cell
Jang, J. K., Pham, T. H., Chang, I. S., Kang, K. H., Moon, H., Cho, K. S., & Kim, B. H. (2004) · Process Biochemistry · doi:10.1016/s0032-9592(03)00203-6 · Cited by 494
Methods for assessing biochemical oxygen demand (BOD): A review
Jouanneau, S., Recoules, L., Durand, M. J., Boukabache, A., Picot, V., Primault, Y., Lakel, A., Sengelin, M., Barillon, B., & Thouand, G. (2014) · Water Research · doi:10.1016/j.watres.2013.10.066 · Cited by 469
Lei, Y., Chen, W., & Mulchandani, A. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2005.11.065 · Cited by 406
Grattieri, M., & Minteer, S. D. (2018) · ACS Sensors · doi:10.1021/acssensors.7b00818 · Cited by 312
Metadata
- Authors
- Karube, I., Matsunaga, T., Mitsuda, S., & Suzuki, S.
- Venue
- Biotechnology and Bioengineering
- Publisher
- Wiley
- Published
- 1977-10
- Volume
- 19
- Issue
- 10
- Pages
- 1535-1547
- ISSN
- 0006-3592 (ISSN-L)
- 1097-0290
- OpenAlex
- W2110645902
- Cited by
- 362
- References
- 0
- FWCI
- 30.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Microbial electrode BOD sensors. https://app.cochat.ai/papers/10.1002/bit.260191010
- The paper
- Karube, I., Matsunaga, T., Mitsuda, S., & Suzuki, S. (1977). Microbial electrode BOD sensors. Biotechnology and Bioengineering. https://doi.org/10.1002/bit.260191010
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.