CoChat

Interaction of infectious viral particles with a quaternary ammonium chlorid (QAC) surface

Open access
Tsao, I‐Fu, Wang, Henry Y., Shipman, Charles · 1989 · Biotechnology and Bioengineering

The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.

Abstract

The antiviral activity of a surface-bonded quaternary ammonium chloride (QAC) was examined in this study. The mechanism of inactivation was elucidated by a combination of infectivity assay, radioactive labeling assay, and sedimentation analysis. Although the virions are still infectious when attached onto the chemically modified surface, we found these viruses are inactivated if they are eluted from the surface. The inactivation is caused by the disruption of the viral envelope with subsequent release of the nucleocapsid. No evidence indicates the released nucleocapsid is further disrupted. An enveloped virus shows a much higher affinity for the QAC-treated surface than a nonenveloped one due to hydrophobic interaction. The QAC-treated beads can effectively remove the enveloped viruses at low protein concentrations. The titer of herpes simplex virus was reduced by a factor of nearly 5 logarithm units in a 0.5 wt % bovine serum albumin solution with less that 10% protein loss. However, the presence of proteins in the solution reduced both the rate and capacity of this nonspecific adsorption-inactivation process. As a consequence, the removal efficiency is relatively poor in solutions with high protein content.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/bit.260340508

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 17 references

Research works printed but not linked: 4

  1. A. N. Petrocci, in Disinfection, Sferilizarion and Preservation, 3rd ed., S. S . Block, Ed. (Lea & Febiger, Philadelphia, 1983), p. 309.
  2. A. J. Isquith, E. A. Abbott, and P. A. Waters, Appl. Environ. Micro- biol., 24, 859 (1972). · doi:10.1128/am.24.6.859-863.1972 · Paper page
  3. M. Klein and A. Deforest, in Disinfection, Sterilization and Preser- vation. 3rd ed., S. S. Block, Ed. (Lea & Febiger, Philadelphia, 1983). p. 422.
  4. M. Bums, G. I. Kvesitadze, and D. Graves, Biotechnol. Bioeng., 27, 137 (1985).

Cited by

See all 28

Metadata

Authors
Tsao, I., Wang, H. Y., & Shipman, C.
Affiliations
University of Michigan (US)
Corresponding author
Wang, Henry Y.
Venue
Biotechnology and Bioengineering
Publisher
Wiley
Published
1989-08-20
Volume
34
Issue
5
Pages
639-646
ISSN
  • 0006-3592 (ISSN-L)
  • 1097-0290
OpenAlex
W2147207003
Cited by
26
References
16
Citations by year
2026: 1 · 2025: 1 · 2024: 4 · 2022: 4 · 2021: 2 · 2020: 1 · 2019: 1 · 2017: 2 · 2016: 1 · 2015: 2 · 2014: 1 · 2013: 1 · 2012: 1
FWCI
0.00
Type
journal article
Language
en
Open access
Locations
  • Biotechnology and Bioengineering (publishedVersion)
  • PubMed (publishedVersion)
  • Deep Blue (University of Michigan) (submittedVersion)
Topics
  • Life Sciences › Immunology and Microbiology › Applied Microbiology and Biotechnology › Antimicrobial agents and applications
  • Health Sciences › Medicine › Infectious Diseases › Infection Control in Healthcare
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
Keywords
quaternary ammonium chloride, antiviral surfaces, virus inactivation, herpes simplex virus, hydrophobic interactions, viral attachment, protein interference, surface disinfection, infectivity assay

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.