The DOI matches its Crossref record.
Composition of cell‐polymer cartilage implants
Abstract
Cartilage implants for potential in vivo use for joint repair or reconstructive surgery can be created in vitro by growing chondrocytes on biodegradable polymer scaffolds. Implants 1 cm in diameter by 0.176 cm thick were made using isolated calf chondrocytes and polyglucolic acid (PGA). By 6 weeks, the total amount of glycosaminoglycan (GAG) and collagen (types I and II) increased to 46% of the implant dry weight; there was a corresponding decrease in the mass of PGA. Implant biochemical and histological compositions depended on initial cell density, scaffold thickness, and the methods of cell seeding and implant culture. Implants seeded at higher initial cell densities reached higher GAG contents (total and per cell), presumably due to cooperative cell‐to‐cell interactions. Thicker implants had lower GAG and collagen contents due to diffusional limitations. Implants that were seeded and cultured under mixed conditions grew to be thicker and more spatially uniform with respect to the distribution of cells, matrix, and remaining polymer than those seeded and/or cultured statically. Implants from mixed cultures had a 20‐40‐μm thick superficial zone of flat cells and collagen oriented parallel to the surface and a deep zone with perpendicular columns of cells surrounded by GAG Mixing during cell seeding and culture resulted in a more even cell distribution ad enhanced nutrient diffusion which could be related to a more favorable biomechanical environment for chondrogenesis. Cartilage with appropriate for and function for in vivo implantation ca thus be created by selectively stimulating the growth and differentiated function of chondrocytes (i.e., GAG and collagen synthesis) through optimization of the in vitro culture environment. © 1994 John Wiley & Sons, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Biodegradable Polymer Scaffolds for Tissue Engineering
Freed, L. E., Vunjak-Novakovic, G., Biron, R. J., Eagles, D. B., Lesnoy, D. C., Barlow, S. K., & Langer, R. (1994) · Nature Biotechnology · doi:10.1038/nbt0794-689 · Cited by 1,235
Self-citationBiomaterials in Tissue Engineering
Hubbell, J. A. (1995) · Nature Biotechnology · doi:10.1038/nbt0695-565 · Cited by 1,060
Mauck, R. L., Soltz, M. A., Wang, C. C. B., Wong, D. D., Chao, P.-H. G., Valhmu, W. B., Hung, C. T., & Ateshian, G. A. (2000) · Journal of Biomechanical Engineering · doi:10.1115/1.429656 · Cited by 976
Polymeric biomaterials for tissue and organ regeneration
Seal, B. (2001) · Materials Science and Engineering: R: Reports · doi:10.1016/s0927-796x(01)00035-3 · Cited by 892
Bone formation by three-dimensional stromal osteoblast culture in biodegradable polymer scaffolds
Ishaug, S. L., Crane, G. M., Miller, M. J., Yasko, A. W., Yaszemski, M. J., & Mikos, A. G. (1997) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199707)36:1<17::aid-jbm3>3.0.co;2-o · Cited by 833
Metadata
- Authors
- Freed, L. E., Marquis, J. C., Langer, R., Vunjak‐Novakovic, G., & Emmanual, J.
- Venue
- Biotechnology and Bioengineering
- Publisher
- Wiley
- Published
- 1994-03-25
- Volume
- 43
- Issue
- 7
- Pages
- 605-614
- ISSN
- 0006-3592 (ISSN-L)
- 1097-0290
- OpenAlex
- W1982713034
- Cited by
- 179
- References
- 0
- FWCI
- 7.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Composition of cell‐polymer cartilage implants. https://app.cochat.ai/papers/10.1002/bit.260430710
- The paper
- Freed, L. E., Marquis, J. C., Langer, R., Vunjak‐Novakovic, G., & Emmanual, J. (1994). Composition of cell‐polymer cartilage implants. Biotechnology and Bioengineering. https://doi.org/10.1002/bit.260430710
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.