Spatial distribution of mammalian cells dictated by material surface chemistry
The DOI matches its Crossref record.
Abstract
Anisotropic cell culture surfaces patterned with amino and alkylsilanes can guide cell distribution and provide an approach to study important processes involved in tissue engineering, such as cell attachment and locomotion. By combining photolithographic and silane coupling techniques, glass coverslips were patterned with either n‐octadecyldimethylchlorosilane (ODDMS) or dimethyldichlorosilane (DMS), and N‐(2‐aminoethyl)‐3‐aminopropyl‐trimethoxysilane (EDS). The alkylsilanes, theoretically, have similar methyl and methylene groups exposed at the surface but different structures, with DMS being amorphous and ODDMS ordered. Neuroblastoma cells, osteosarcoma cells, and fibroblasts plated on surfaces patterned with EDS/ODDMS and EDS/DMS specifically localized on the EDS regions, but distributed randomly on ODDMS/DMS patterned surfaces. The preferential assembly of cells onto EDS regions did not depend on the structure of the adjacent alkylsilane regions and was a time‐dependent process. Angle dependent x‐ray photoelectron spectroscopy (XPS) and contact angle measurements indicated that EDS was imobilized on glass as a fractional hydrophilic monolayer, and ODDMS and DMS were bound as patchy amorphous hydrophobic multilayers. Neither surface coverage nor thickness of the overlayer seemed to be as important as surface chemistry, or charge, in guiding mammalian cell distribution. These results are consistent with the concept that mammalian cells attach to and are guided by positively charged surfaces.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Biomaterials in Tissue Engineering
Hubbell, J. A. (1995) · Nature Biotechnology · doi:10.1038/nbt0695-565 · Cited by 1,060
Faucheux, N., Schweiss, R., Lützow, K., Werner, C., & Groth, T. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.09.069 · Cited by 729
Micropatterned Surfaces for Control of Cell Shape, Position, and Function
Chen, C. S., Mrksich, M., Huang, S., Whitesides, G. M., & Ingber, D. E. (1998) · Biotechnology Progress · doi:10.1021/bp980031m · Cited by 706
Webb, K., Hlady, V., & Tresco, P. A. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(19980905)41:3<422::aid-jbm12>3.0.co;2-k · Cited by 689
A novel method to fabricate bioabsorbable scaffolds
Whang, K., Thomas, C. H., Healy, K. E., & Nuber, G. (1995) · Polymer · doi:10.1016/0032-3861(95)93115-3 · Cited by 639
Self-citation
Metadata
- Authors
- Healy, K. E., Lom, B., & Hockberger, P. E.
- Venue
- Biotechnology and Bioengineering
- Publisher
- Wiley
- Published
- 1994-04-05
- Volume
- 43
- Issue
- 8
- Pages
- 792-800
- ISSN
- 0006-3592 (ISSN-L)
- 1097-0290
- OpenAlex
- W2164645301
- Cited by
- 102
- References
- 0
- FWCI
- 1.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Spatial distribution of mammalian cells dictated by material surface chemistry. https://app.cochat.ai/papers/10.1002/bit.260430814
- The paper
- Healy, K. E., Lom, B., & Hockberger, P. E. (1994). Spatial distribution of mammalian cells dictated by material surface chemistry. Biotechnology and Bioengineering. https://doi.org/10.1002/bit.260430814
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.