An NIR‐Based PAT Approach for Real‐Time Control of Loading in Protein A Chromatography in Continuous Manufacturing of Monoclonal Antibodies

Thakur, Garima, Hebbi, Vishwanath, Rathore, Anurag S.·2020·Biotechnology and Bioengineering

Abstract

Control of column loading in Protein A chromatography is a crucial part of development of robust and flexible process platforms for continuous production of monoclonal antibody (mAb) products. In this paper, we propose a control system that uses near infrared spectroscopy (NIRS) flow cells to accomplish the above. Two applications have been demonstrated using a periodic counter‐current continuous chromatography setup. The first application involves use of single NIR flow cell before the inlet of the loading column to measure the concentration of mAb in the harvested broth. Measurement was in real‐time (every 3 s) and within ±0.05 mg/ml, significantly better than making UV‐based concentration estimations. The second application involved use of an additional NIR flow cell at the outlet of the loading column to measure column breakthrough in real time. The concentration data was transferred to a Python‐based monitoring and control algorithm layered over a Cadence BioSMB system. The program could successfully run a three‐column periodic counter current method on the BioSMB whereas controlling loading to ensure optimal resin utilization in each loading cycle phase based on precharacterized dynamic binding capacity models, whereas maintaining periodic elutions. The system was tested with multiple perturbations in harvest concentration, modeled after deviations that could arise downstream of a perfusion cell culture system. The results show that the proposed control is a spectroscopy‐based process analytical technology tool that facilitates real time monitoring and control of loading in process chromatography. It is adaptable to any continuous chromatography equipment and is very well suited for implementation in a continuous mAb production train.

Integrity signals

Registry

Crossref · 10.1002/bit.27236

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • FT-NIR has been used for on-line monitoring of column loading in Protein A chromatography, measuring target product concentration in harvested broth and column effluent every 3 s and detecting column breakthrough with high accuracy.

    “Thakur et al. monitored the column loading using an on‐line FT‐NIR setup, where the target product concentration in both the harvested broth and column effluent from Protein A chromatography was measured in real time, for every 3 s and column breakthrough was detected successfully with high accuracy [63].”

Cited by

Sorted by citations

Authors
Thakur, G., Hebbi, V., & Rathore, A. S.
Affiliations
Department of Chemical Engineering Indian Institute of Technology New Delhi India
Venue
Biotechnology and Bioengineering
Publisher
Wiley
Published
2019-12-11
Volume
117
Issue
3
Pages
673-686
ISSN
  • 0006-3592
  • 1097-0290
Cited by
62
References
0
Language
en
Funders
Department of Biotechnology , Ministry of Science and Technology (BT/COE/34/SP15097/2015)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review