Real‐Time Monitoring of Quality Attributes by In‐Line Fourier Transform Infrared Spectroscopic Sensors at Ultrafiltration and Diafiltration of Bioprocess

Wasalathanthri, Dhanuka P., Feroz, Hasin, Puri, Neha, Hung, Jessica, Lane, Gregory, Holstein, Melissa, Chemmalil, Letha, Both, Douglas +3 more·2020·Biotechnology and Bioengineering

Abstract

Technologies capable of monitoring product quality attributes and process parameters in real time are becoming popular due to the endorsement of regulatory agencies and also to support the agile development of biotherapeutic pipelines. The utility of vibrational spectroscopic techniques such as Fourier transform mid‐infrared (Mid‐IR) and multivariate data analysis (MVDA) models allows the prediction of multiple critical attributes simultaneously in real time. This study reports the use of Mid‐IR and MVDA model sensors for monitoring of multiple attributes (excipients and protein concentrations) in real time (measurement frequency of every 40 s) at ultrafiltration and diafiltration (UF/DF) unit operation of biologics manufacturing. The platform features integration of fiber optic Mid‐IR probe sensors to UF/DF set up at the bulk solution and through a flow cell at the retentate line followed by automated Mid‐IR data piping into a process monitoring software platform with pre‐loaded partial least square regression (PLS) chemometric models. Data visualization infrastructure is also built‐in to the platform so that upon automated PLS prediction of excipients and protein concentrations, the results were projected in a graphical or numerical format in real time. The Mid‐IR predicted concentrations of excipients and protein show excellent correlation with the offline measurements by traditional analytical methods. Absolute percent difference values between Mid‐IR predicted results and offline reference assay results were ≤5% across all the excipients and the protein of interest; which shows a great promise as a reliable process analytical technology tool.

Integrity signals

Registry

Crossref · 10.1002/bit.27532

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • ATR-FTIR has been implemented in-line during the UFDF step to monitor protein concentration with a simple one-point calibration algorithm or both protein and various excipient concentrations with a multivariate data analysis model.

    “Recently, ATR‐FTIR has also been implemented in‐line during the UFDF step, to monitor the protein concentration with a simple one‐point calibration algorithm [55] or both protein and various excipient concentrations, with a multi‐variate data analysis (MVDA) model [56].”
  • In ATR-FTIR monitoring during UFDF, rapid measurements in seconds and accurate concentration predictions were achieved.

    “In both cases, rapid measurements in seconds and accurate concentration predictions were achieved.”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Wasalathanthri, D. P., Feroz, H., Puri, N., Hung, J., Lane, G., Holstein, M., Chemmalil, L., Both, D., Ghose, S., Ding, J., & Li, Z. J.
Affiliations
  • Biologics Process Development Bristol Myers Squibb Company Devens Massachusetts
  • Engineering Technologies Bristol Myers Squibb Company New Brunswick New Jersey
Venue
Biotechnology and Bioengineering
Publisher
Wiley
Published
2020-08-18
Volume
117
Issue
12
Pages
3766-3774
ISSN
  • 0006-3592
  • 1097-0290
Cited by
35
References
2
Language
en

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review