Realization of Digital Twin for Dynamic Control Toward Sample Variation of Ion Exchange Chromatography in Antibody Separation
Abstract
Digital twin (DT) is a virtual and digital representation of physical objects or processes. In this paper, this concept is applied to dynamic control of the collection window in the ion exchange chromatography (IEC) toward sample variations. A possible structure of a feedforward model‐based control DT system was proposed. Initially, a precise IEC mechanistic model was established through experiments, model fitting, and validation. The average root mean square error (RMSE) of fitting and validation was 8.1% and 7.4%, respectively. Then a model‐based gradient optimization was performed, resulting in a 70.0% yield with a remarkable 11.2% increase. Subsequently, the DT was established by systematically integrating the model, chromatography system, online high‐performance liquid chromatography, and a server computer. The DT was validated under varying load conditions. The results demonstrated that the DT could offer an accurate control with acidic variants proportion and yield difference of less than 2% compared to the offline analysis. The embedding mechanistic model also showed a positive predictive performance with an average RMSE of 11.7% during the DT test under >10% sample variation. Practical scenario tests indicated that tightening the control target could further enhance the DT robustness, achieving over 98% success rate with an average yield of 72.7%. The results demonstrated that the constructed DT could accurately mimic real‐world situations and perform an automated and flexible pooling in IEC. Additionally, a detailed methodology for applying DT was summarized.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Digital twins have been recently constructed for IEX processes, systematically integrated with the HPLC system and a server computer; the DT predicted elution profiles, enabling automated collection control.
“For instance, DTs have been recently constructed for ion‐exchange chromatography (IEX) processes, and are systematically integrated with the HPLC system and a server computer. The DT was able to predict the elution profiles, enabling automated collection control [114].”
From Current PAT Landscape in the Downstream Processing of Biopharmaceuticals (2025) · cites this paper as [114]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
No references could be resolved yet.
Research works printed but not linked: 37
- Babi, D. K., Griesbach, J., Hunt, S., Insaidoo, F., Roush, D., Todd, R., Staby, A., Welsh, J., & Wittkopp, F. (2022). Opportunities and challenges for model utilization in the biopharmaceutical industry: Current versus future state. Current Opinion in Chemical Engineering, 36, 100813. https://doi.org/10.1016/j.coche.2022.100813 · DOI
- Bideault, G., Scaccia, A., Zahel, T., Landertinger, R. W., & Daluwatte, C. (2021). Verification and validation of computational models used in biopharmaceutical manufacturing: Potential application of the ASME verification and validation 40 standard and FDA proposed AI/ML model life cycle management framework. Journal of Pharmaceutical Sciences, 110(4), 1540-1544. https://doi.org/10.1016/j.xphs.2021. 01.016 · DOI
- Brestrich, N., Sanden, A., Kraft, A., McCann, K., Bertolini, J., & Hubbuch, J. (2015). Advances in inline quantification of co-eluting proteins in chromatography: Process-data-based model calibration and applica- tion towards real-life separation issues. Biotechnology and Bioengineering, 112(7), 1406-1416. https://doi.org/10.1002/bit. 25546 · DOI
- Briskot, T., Hahn, T., Huuk, T., Wang, G., Kluters, S., Studts, J., Wittkopp, F., Winderl, J., Schwan, P., Hagemann, I., Kaiser, K., Trapp, A., Stamm, S. M., Koehn, J., Malmquist, G., & Hubbuch, J. (2021). Analysis of complex protein elution behavior in preparative ion exchange processes using a colloidal particle adsorption model. Journal of Chromatography A, 1654, 462439. https://doi.org/10. 1016/j.chroma.2021.462439 · DOI
- Capito, F., Skudas, R., Kolmar, H., & Hunzinger, C. (2015). At-line mid infrared spectroscopy for monitoring downstream processing unit operations. Process Biochemistry, 50(6), 997-1005. https://doi.org/ 10.1016/j.procbio.2015.03.005 · DOI
- Chen, R., Chen, X. J., Shi, C., Jiao, B., Shi, Y., Yao, B., Lin, D. Q., Gong, W., & Hsu, S. (2022). Converting a mAb downstream process from batch to continuous using process modeling and process analytical technol- ogy. Biotechnology Journal, 17(11), 2100351. https://doi.org/10. 1002/biot.202100351 · DOI
- Chen, Y., Yang, O., Sampat, C., Bhalode, P., Ramachandran, R., & Ierapetritou, M. (2020). Digital twins in pharmaceutical and biopharmaceutical manufacturing: A literature review. Processes, 8(9), 1088. https://doi.org/10.3390/pr8091088 · DOI
- Chen, Y. C., Yao, S. J., & Lin, D. Q. (2022). Parameter-by-parameter method for steric mass action model of ion exchange chromatogra- phy: Theoretical considerations and experimental verification. Journal of Chromatography A, 1680, 463418. https://doi.org/10. 1016/j.chroma.2022.463418 · DOI
- Diedrich, J., Heymann, W., Leweke, S., Hunt, S., Todd, R., Kunert, C., Johnson, W., & von Lieres, E. (2017). Multi-state steric mass action model and case study on complex high loading behavior of mAb on ion exchange tentacle resin. Journal of Chromatography A, 1525, 60-70. https://doi.org/10.1016/j.chroma.2017.09.039 · DOI
- Feidl, F., Vogg, S., Wolf, M., Podobnik, M., Ruggeri, C., Ulmer, N., Wälchli, R., Souquet, J., Broly, H., Butté, A., & Morbidelli, M. (2020). Process-wide control and automation of an integrated continuous manufacturing platform for antibodies. Biotechnology and Bioengineering, 117(5), 1367-1380. https://doi.org/10.1002/bit. 27296 · DOI
- Fekete, S., Beck, A., Veuthey, J. L., & Guillarme, D. (2015). Ion-exchange chromatography for the characterization of biopharmaceuticals. Journal of Pharmaceutical and Biomedical Analysis, 113, 43-55. https://doi.org/10.1016/j.jpba.2015.02.037 · DOI
- Gagliardi, T. M., Chelikani, R., Yang, Y., Tuozzolo, G., & Yuan, H. (2019). Development of a novel, high-throughput screening tool for efficient perfusion-based cell culture process development. Biotechnology Progress, 35(4), e2811. https://doi.org/10.1002/btpr.2811 · DOI
- Gomis-Fons, J., Schwarz, H., Zhang, L., Andersson, N., Nilsson, B., Castan, A., Solbrand, A., Stevenson, J., & Chotteau, V. (2020). Model-based design and control of a small-scale integrated continuous end-to-end mAb platform. Biotechnology Progress, 36(4), e2995. https://doi.org/10.1002/btpr.2995 · DOI
- Großhans, S., Rüdt, M., Sanden, A., Brestrich, N., Morgenstern, J., Heissler, S., & Hubbuch, J. (2018). In-line Fourier-transform infrared spectroscopy as a versatile process analytical technology for preparative protein chromatography. Journal of Chromatography A, 1547, 37-44. https://doi.org/10.1016/j.chroma.2018.03.005 · DOI
- Haberger, M., Heidenreich, A. K., Hook, M., Fichtl, J., Lang, R., Cymer, F., Adibzadeh, M., Kuhne, F., Wegele, H., Reusch, D., Bonnington, L., & Bulau, P. (2021). Multiattribute monitoring of antibody charge variants by cation-exchange chromatography coupled to native mass spectrometry. Journal of the American Society for Mass Spectrometry, 32(8), 2062-2071. https://doi.org/10.1021/jasms. · DOI
- 0c00446 · DOI
- Hahn, T., Huuk, T., Heuveline, V., & Hubbuch, J. (2015). Simulating and optimizing preparative protein chromatography with ChromX. Journal of Chemical Education, 92(9), 1497-1502. https://doi.org/ 10.1021/ed500854a · DOI
- Helgers, H., Hengelbrock, A., Schmidt, A., & Strube, J. (2021). Digital twins for continuous mRNA production. Processes, 9(11), 1967. https:// doi.org/10.3390/pr9111967 · DOI
- Huuk, T. C., Hahn, T., Doninger, K., Griesbach, J., Hepbildikler, S., & Hubbuch, J. (2017). Modeling of complex antibody elution behavior under high protein load densities in ion exchange chromatography using an asymmetric activity coefficient. Biotechnology Journal, 12(3), 1600336. https://doi.org/10.1002/biot.201600336 · DOI
- Kumar, V., Leweke, S., von Lieres, E., & Rathore, A. S. (2015). Mechanistic modeling of ion-exchange process chromatography of charge variants of monoclonal antibody products. Journal of Chromatography A, 1426, 140-153. https://doi.org/10.1016/j.chroma.2015.11.062 · DOI
- Narayanan, H., Seidler, T., Luna, M. F., Sokolov, M., Morbidelli, M., & Butté, A. (2021). Hybrid models for the simulation and prediction of chromatographic processes for protein capture. Journal of Chromatography A, 1650, 462248. https://doi.org/10.1016/j. chroma.2021.462248 · DOI
- Narayanan, H., Sponchioni, M., & Morbidelli, M. (2022). Integration and digitalization in the manufacturing of therapeutic proteins. Chemical Engineering Science, 248, 117159. https://doi.org/10.1016/j.ces. 2021.117159 · DOI
- O'Connor, T. F., Yu, L. X., & Lee, S. L. (2016). Emerging technology: A key enabler for modernizing pharmaceutical manufacturing and advanc- ing product quality. International Journal of Pharmaceutics, 509(1-2), 492-498. https://doi.org/10.1016/j.ijpharm.2016.05.058 · DOI
- Osberghaus, A., Hepbildikler, S., Nath, S., Haindl, M., Von Lieres, E., & Hubbuch, J. (2012). Optimizing a chromatographic three component separation: A comparison of mechanistic and empiric modeling approaches. Journal of Chromatography A, 1237, 86-95. https://doi. org/10.1016/j.chroma.2012.03.029 · DOI
- Phanden, R. K., Sharma, P., & Dubey, A. (2021). A review on simulation in digital twin for aerospace, manufacturing and robotics. Materials Today: Proceedings, 38, 174-178. https://doi.org/10.1016/j.matpr. 2020.06.446 · DOI
- Pirrung, S. M., van der Wielen, L. A. M., van Beckhoven, R. F. W. C., van de Sandt, E. J. A. X., Eppink, M. H. M., & Ottens, M. (2017). Optimization of biopharmaceutical downstream processes sup- ported by mechanistic models and artificial neural networks. Biotechnology Progress, 33(3), 696-707. https://doi.org/10.1002/ btpr.2435 · DOI
- Rathore, A. S., Yu, M., Yeboah, S., & Sharma, A. (2008). Case study and application of process analytical technology (PAT) towards biopro- cessing: Use of on-line high-performance liquid chromatography (HPLC) for making real-time pooling decisions for process chroma- tography. Biotechnology and Bioengineering, 100(2), 306-316. https://doi.org/10.1002/bit.21759 · DOI
- Rischawy, F., Briskot, T., Hopf, N., Saleh, D., Wang, G., Kluters, S., Studts, J., & Hubbuch, J. (2023). Connected mechanistic process modeling to predict a commercial biopharmaceutical downstream process. Computers & Chemical Engineering, 176, 108292. https:// doi.org/10.1016/j.compchemeng.2023.108292 · DOI
- Rischawy, F., Briskot, T., Schimek, A., Wang, G., Saleh, D., Kluters, S., Studts, J., & Hubbuch, J. (2022). Integrated process model for the prediction of biopharmaceutical manufacturing chromatography and adjustment steps. Journal of Chromatography A, 1681, 463421. https://doi.org/10.1016/j.chroma.2022.463421 · DOI
- Rüdt, M., Gillet, F., Heege, S., Hitzler, J., Kalbfuss, B., & Guélat, B. (2015). Combined Yamamoto approach for simultaneous estimation of adsorption isotherm and kinetic parameters in ion-exchange chromatography. Journal of Chromatography A, 1413, 68-76. https://doi.org/10.1016/j.chroma.2015.08.025 · DOI
- Seelinger, F., Wittkopp, F., von Hirschheydt, T., & Frech, C. (2022). Application of the steric mass action formalism for modeling under high loading conditions: Part 2. Investigation of high loading and column overloading effects. Journal of Chromatography A, 1676, 463266. https://doi.org/10.1016/j.chroma.2022.463266 · DOI
- Seelinger, F., Wittkopp, F., von Hirschheydt, T., & Frech, C. (2023). Anti-Langmuir elution behavior of a bispecific monoclonal antibody in cation exchange chromatography: Mechanistic modeling using a pH-dependent self-association steric mass action isotherm. Journal of Chromatography A, 1689, 463730. https://doi.org/10.1016/j. chroma.2022.463730 · DOI
- Tang, S. Y., Yuan, Y. H., Chen, Y. C., Yao, S. J., Wang, Y., & Lin, D. Q. (2023). Physics-informed neural networks to solve lumped kinetic model for chromatography process. Journal of Chromatography A, 1708, 464346. https://doi.org/10.1016/j.chroma.2023.464346 · DOI
- Thakur, G., Hebbi, V., & Rathore, A. S. (2021). Near infrared spectroscopy as a PAT tool for monitoring and control of protein and excipient concentration in ultrafiltration of highly concentrated antibody formulations. International Journal of Pharmaceutics, 600, 120456. https://doi.org/10.1016/j.ijpharm.2021.120456 · DOI · Paper page
- Tiwari, A., Masampally, V. S., Agarwal, A., & Rathore, A. S. (2023). Digital twin of a continuous chromatography process for mAb purification: Design and model-based control. Biotechnology and Bioengineering, 120(3), 748-766. https://doi.org/10.1002/bit.28307 · DOI
- Wagner, K., Miliotis, T., Marko-Varga, G., Bischoff, R., & Unger, K. K. (2002). An automated on-line multidimensional HPLC system for protein and peptide mapping with integrated sample preparation. Analytical Chemistry, 74(4), 809-820. https://doi.org/10.1021/ ac010627f · DOI
- Wang, J., Chen, J., Studts, J., & Wang, G. (2023). In-line product quality monitoring during biopharmaceutical manufacturing using computa- tional Raman spectroscopy. mAbs, 15(1), 220149. https://doi.org/ 10.1080/19420862.2023.2220149 · DOI · Paper page
Cited by
Sorted by citations
Current PAT Landscape in the Downstream Processing of Biopharmaceuticals
Sathiyapriyan, P., Mukherjee, S., Vogel, T., Essen, L., Boerema, D., Vey, M., & Kalina, U. (2025) · Analytical Science Advances · doi:10.1002/ansa.70013 · Cited by 45 · see citing works
- Authors
- Shi, C., Chen, X., Zhong, X., Yang, Y., Lin, D., & Chen, R.
- Affiliations
- Process Development Downstream, Shanghai Engineering Research Center of Anti‐tumor Biological Drugs Shanghai Henlius Biotech, Inc. Shanghai China
- Key Laboratory of Biomass Chemical Engineering of Ministry of Education, College of Chemical and Biological Engineering Zhejiang University Hangzhou China
- Venue
- Biotechnology and Bioengineering
- Publisher
- Wiley
- Published
- 2024-01-17
- Volume
- 121
- Issue
- 5
- Pages
- 1702-1715
- ISSN
- 0006-3592
- 1097-0290
- Cited by
- 13
- References
- 0
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review