The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Mid-term survival after abdominal aortic aneurysm surgery predicted by cardiopulmonary exercise testing
Open accessAbstract
Background: Cardiopulmonary exercise (CPX) testing measures how efficiently subjects meet increased metabolic demand. This study aimed to determine whether preoperative CPX testing predicted postoperative survival following elective abdominal aortic aneurysm (AAA) repair. Methods: Some 130 patients had CPX testing before elective open AAA repair. Additional preoperative, operative and postoperative variables were recorded prospectively. Median follow-up was 35 months. The correlation of variables with survival was assessed by single and multiple regression analyses. Results: CPX testing identified 30 of 130 patients who had been unfit before surgery. Two years after surgery the Kaplan–Meier survival estimate was 55 per cent for the 30 unfit patients, compared with 97 per cent for the 100 fit patients. The absolute difference in survival between these two groups at 2 years was 42 (95 per cent confidence interval 18 to 65) per cent (P < 0·001). Conclusion: Preoperative CPX testing, combined with simple co-morbidity scoring, identified patients unlikely to survive in the mid-term, even after successful AAA repair.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Le Gall, J.-R. (1993) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.270.24.2957 · Cited by 7,773
A new method for detecting anaerobic threshold by gas exchange
Beaver, W. L., Wasserman, K., & Whipp, B. J. (1986) · Journal of Applied Physiology · doi:10.1152/jappl.1986.60.6.2020 · Cited by 4,103
Cited by
Ross, R., Blair, S. N., Arena, R., Church, T. S., Després, J.-P., Franklin, B. A., Haskell, W. L., Kaminsky, L. A., Levine, B. D., Lavie, C. J., et al. (2016) · Circulation · doi:10.1161/cir.0000000000000461 · Cited by 2,486
Fleisher, L. A., Fleischmann, K. E., Auerbach, A. D., Barnason, S. A., Beckman, J. A., Bozkurt, B., Davila-Roman, V. G., Gerhard-Herman, M. D., Holly, T. A., Kane, G. C., et al. (2014) · Circulation · doi:10.1161/cir.0000000000000106 · Cited by 1,820
Fleisher, L. A., Fleischmann, K. E., Auerbach, A. D., Barnason, S. A., Beckman, J. A., Bozkurt, B., Davila-Roman, V. G., Gerhard-Herman, M. D., Holly, T. A., Kane, G. C., et al. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.07.944 · Cited by 1,320
Pathophysiology and epidemiology of abdominal aortic aneurysms
Nordon, I. M., Hinchliffe, R. J., Loftus, I. M., & Thompson, M. M. (2011) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2010.180 · Cited by 822
Fleisher, L. A., Fleischmann, K. E., Auerbach, A. D., Barnason, S. A., Beckman, J. A., Bozkurt, B., Davila-Roman, V. G., Gerhard-Herman, M. D., Holly, T. A., Kane, G. C., et al. (2014) · Circulation · doi:10.1161/cir.0000000000000105 · Cited by 800
Metadata
- Authors
- Carlisle, J., & Swart, M.
- Venue
- British Journal of Surgery
- Publisher
- Oxford University Press (OUP)
- Published
- 2007-04-17
- Volume
- 94
- Issue
- 8
- Pages
- 966-969
- ISSN
- 0007-1323 (ISSN-L)
- 1365-2168
- OpenAlex
- W1991545170
- Cited by
- 216
- References
- 2
- FWCI
- 7.81
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.