Quantification of malondialdehyde by HPLC‐FL – application to various biological samples
Abstract
Malondialdehyde (MDA) is stabile product of lipid peroxidation (LPO), and therefore MDA is frequently used as a biomarker of LPO. To determine MDA level in various biological samples (human plasma, fish liver tissue and cells in culture), we used an HPLC method with fluorescent detection based on 2-thiobarbituric acid (TBA) assay. The method was validated by the use of spiked pooled plasma samples. In tested concentration range (0.15-3.0 µmol/L) the method was linear (R(2) = 0.9963), the between-day variability (coefficient of variations, CVs) was between 4.7 and 7.6%, the within-day variability CVs was between 2.6 and 6.4% and recovery was between 91.2 and 107.6%. The level of MDA in human plasma (healthy male, non-smokers, 46.3 ± 4.7 years; N = 38) was 2.2 ± 1.4 µmol/L; that in liver tissue of common carp (Cyprinus carpio; N = 12) was 0.02 ± 0.004 µmol/g tissue, and in cultured cells (human laryngeal carcinoma cells; N = 10) it was 0.18 ± 0.02 nmol/mg proteins. The HPLC-FL method is rapid, accurate and reliable to follow the extent of LPO in various biological samples, particularly in samples in which a low level of MDA is expected, such as cells in culture. Owing to the rapid analytical process and run time, it can be used for routine analysis of MDA in clinical laboratory.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Further methods such as HPLC with UV or fluorescence detection have been developed to improve specificity of MDA measurement.
“Beside this assay, further methods have been developed in order to improve the specificity of MDA measurement, such as HPLC combined with UV or fluorescence detection [182,184].”
From Protein oxidation - Formation mechanisms, detection and relevance as biomarkers in human diseases (2021) · cites this paper as [184]
Cited by
Sorted by citations
Protein oxidation - Formation mechanisms, detection and relevance as biomarkers in human diseases
Kehm, R., Baldensperger, T., Raupbach, J., & Höhn, A. (2021) · Redox Biology · doi:10.1016/j.redox.2021.101901 · Cited by 348 · see citing works
“Beside this assay, further methods have been developed in order to improve the specificity of MDA measurement, such as HPLC combined with UV or fluorescence detection [182,184].”
Method
- Authors
- Domijan, A., Ralić, J., Radić Brkanac, S., Rumora, L., & Žanić‐Grubišić, T.
- Affiliations
- University of Zagreb (HR)
- Galapagos (Croatia) (HR)
- University of Zagreb Faculty of Science, Department of Biology Zagreb Croatia
- Corresponding author
- Domijan, Ana‐Marija
- Venue
- Biomedical Chromatography
- Publisher
- Wiley
- Published
- 2014-10-30
- Volume
- 29
- Issue
- 1
- Pages
- 41-46
- ISSN
- 0269-3879 (ISSN-L)
- 1099-0801
- OpenAlex
- W1544314093
- Cited by
- 98
- References
- 0
- Citations by year
- 2026: 6 · 2025: 6 · 2024: 18 · 2023: 12 · 2022: 11 · 2021: 11 · 2020: 8 · 2019: 8 · 2018: 9 · 2017: 4 · 2016: 5
- FWCI
- 2.11
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Biomedical Chromatography (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Biochemistry › Antioxidant Activity and Oxidative Stress
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Redox biology and oxidative stress
- Physical Sciences › Chemistry › Organic Chemistry › Edible Oils Quality and Analysis
- Keywords
- malondialdehyde, lipid peroxidation, HPLC-fluorescence detection, method validation, human plasma, oxidative stress biomarkers, clinical laboratory testing
- MeSH terms
- Animals, Chromatography, High Pressure Liquid, Humans, Liver, Malondialdehyde, Spectrometry, Fluorescence, Thiobarbiturates, Reproducibility of Results, Linear Models, Cell Line, Tumor
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review