Simultaneous determination of D‐ and L‐serine in rat brain microdialysis sample using a column‐switching HPLC with fluorimetric detection
The DOI matches its Crossref record.
Abstract
Both d‐ and l‐serine in rat brain microdialysis sample were simultaneously determined by pre‐column fluorescence derivatization with 4‐fluoro‐7‐nitro‐2,1,3‐benzoxadiazole (NBD‐F), separation of the derivatives on ODS column, TSKgel ODS‐80TsQA, followed by Pirkle type chiral columns, Sumichiral OA‐2500 (S), which gave a sufficient enantiomeric separation of NBD–d‐serine and NBD‐l‐serine, and fluorimetric detection at a wavelength of 540 nm with an excitation wavelength of 470 nm. The peaks of NBD–d‐serine and NBD–l‐serine in the rat brain microdialysis sample were clearly found, and the validation study showed satisfactory results; the precision and accuracy were within 5.14 and 109%, respectively. Using the proposed HPLC method, the time‐course profile of d‐serine concentration in rat prefrontal cortex following intraperitoneal administration of d‐serine was investigated. As a consequence, d‐serine appeared to be rapidly distributed in the brain, and then decreased gradually with time in the extracellular fluid of the rat prefrontal cortex. The proposed HPLC method will be useful for in vivo studies on d‐serine, which acts as a coagonist for N‐methyl‐d‐aspartate receptor, to the extracellular fluid of rat brain. Copyright © 2004 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Increased Levels of Glutamate in Brains from Patients with Mood Disorders
Hashimoto, K., Sawa, A., & Iyo, M. (2007) · Biological Psychiatry · doi:10.1016/j.biopsych.2007.03.017 · Cited by 609
Review of recent advances in analytical techniques for the determination of neurotransmitters
Perry, M., Li, Q., & Kennedy, R. T. (2009) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.08.038 · Cited by 367
Astroglial CB1 Receptors Determine Synaptic D-Serine Availability to Enable Recognition Memory
Robin, L. M., Oliveira da Cruz, J. F., Langlais, V. C., Martin-Fernandez, M., Metna-Laurent, M., Busquets-Garcia, A., Bellocchio, L., Soria-Gomez, E., Papouin, T., Varilh, M., et al. (2018) · Neuron · doi:10.1016/j.neuron.2018.04.034 · Cited by 262
Papouin, T., Dunphy, J. M., Tolman, M., Dineley, K. T., & Haydon, P. G. (2017) · Neuron · doi:10.1016/j.neuron.2017.04.021 · Cited by 243
Hashimoto, K., Bruno, D., Nierenberg, J., Marmar, C. R., Zetterberg, H., Blennow, K., & Pomara, N. (2016) · Translational Psychiatry · doi:10.1038/tp.2016.8 · Cited by 90
Metadata
- Authors
- Fukushima, T., Kawai, J., Imai, K., & Toyo'oka, T.
- Venue
- Biomedical Chromatography
- Publisher
- Wiley
- Published
- 2004-07-07
- Volume
- 18
- Issue
- 10
- Pages
- 813-819
- ISSN
- 0269-3879 (ISSN-L)
- 1099-0801
- OpenAlex
- W2063597569
- Cited by
- 91
- References
- 0
- FWCI
- 1.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Simultaneous determination of D‐ and L‐serine in rat brain microdialysis sample using a column‐switching HPLC with fluorimetric detection. https://app.cochat.ai/papers/10.1002/bmc.394
- The paper
- Fukushima, T., Kawai, J., Imai, K., & Toyo'oka, T. (2004). Simultaneous determination of D‐ and L‐serine in rat brain microdialysis sample using a column‐switching HPLC with fluorimetric detection. Biomedical Chromatography. https://doi.org/10.1002/bmc.394
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.