The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Preparation of stable isotope-incorporated peptide internal standards for field desorption mass spectrometry quantification of peptides in biologic tissue
Abstract
Stable isotopes have been incorporated into two opioid pentapeptides, leucine enkephalin and methionine enkephalin, using chemical- and enzymatic-catalyzed reactions. Oxygen-18 from H218O was the stable isotope incorporated. High-performance liquid chromatography separated the chemical reaction mixture into three fractions: hydrolyzed peptide fraction, 18O-incorporated enkephalin, and 18O-incorporated enkephalin ester. Analysis of individual isotopic species (18O2, 18O16O, 16O2) in the latter two fractions was done with field desorption mass spectrometry. Porcine esterase II was used to hydrolyse enkephalin esters and recover stable isotope. Up to 90% 18O2 was incorporated. Yields of 18O2 species for the overall procedure were for leucine enkephalin, 56%, and for methionine enkephalin, 38%. This scheme represents the first fast and facile preparation of a stable isotope-incorporated peptide internal standard for use in measuring peptides in biologic extracts and is readily extended to any peptide with a free carboxyl group. Fast atom bombardment-collision activated dissociation-linked field (B/E) scan mass spectrometry unambiguously locates the two 18O atoms in the carboxyl group of the peptide and not in a peptide amide bond or tyrosine side chain. The two 18O-labeled peptide internal standards were used to measure, in a structurally unambiguous fashion, endogenous leucine enkephalin and methionine enkephalin in thalamus tissue at the ppb level. A microcomputer was used for data acquisition and reduction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Identification of two related pentapeptides from the brain with potent opiate agonist activity
Hughes, J., Smith, T. W., Kosterlitz, H. W., Fothergill, L. A., Morgan, B. A., & Morris, H. R. (1975) · Nature · doi:10.1038/258577a0 · Cited by 3,806
Cited by
Anderson, N. L., & Anderson, N. G. (2002) · Molecular & Cellular Proteomics · doi:10.1074/mcp.r200007-mcp200 · Cited by 4,414
Protein biomarker discovery and validation: the long and uncertain path to clinical utility
Rifai, N., Gillette, M. A., & Carr, S. A. (2006) · Nature Biotechnology · doi:10.1038/nbt1235 · Cited by 1,867
Full dynamic range proteome analysis of S. cerevisiae by targeted proteomics
Picotti, P., Bodenmiller, B., Mueller, L. N., Domon, B., & Aebersold, R. (2009) · Cell · doi:10.1016/j.cell.2009.05.051 · Cited by 744
Targeted Proteomic Quantification on Quadrupole-Orbitrap Mass Spectrometer
Gallien, S., Duriez, E., Crone, C., Kellmann, M., Moehring, T., & Domon, B. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.o112.019802 · Cited by 510
Mass spectrometry approaches to glycomic and glycoproteomic analyses
Ruhaak, L. R., Xu, G., Li, Q., Goonatilleke, E., & Lebrilla, C. B. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00732 · Cited by 395
Metadata
- Authors
- Desiderio, D. M., & Kai, M.
- Venue
- Biological Mass Spectrometry
- Publisher
- Wiley
- Published
- 1983-08
- Volume
- 10
- Issue
- 8
- Pages
- 471-479
- ISSN
- 1076-5174 (ISSN-L)
- 0306-042X
- 1096-9888
- OpenAlex
- W1972927753
- Cited by
- 158
- References
- 1
- FWCI
- 1.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Preparation of stable isotope-incorporated peptide internal standards for field desorption mass spectrometry quantification of peptides in biologic tissue. https://app.cochat.ai/papers/10.1002/bms.1200100806
- The paper
- Desiderio, D. M., & Kai, M. (1983). Preparation of stable isotope-incorporated peptide internal standards for field desorption mass spectrometry quantification of peptides in biologic tissue. Biological Mass Spectrometry. https://doi.org/10.1002/bms.1200100806
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.