Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 180

The DOI matches its Crossref record.

Liquid junction coupling for capillary zone electrophoresis/ion spray mass spectrometry

Lee, Edgar D., Mück, Wolfgang, Henion, Jack D., Covey, Thomas R.·1989·Biological Mass Spectrometry

Abstract

A liquid junction coupling has been developed to couple capillary zone electrophoresis (CZE) with ion spray mass spectrometry. The liquid junction was found to compensate for the different eluent flows required by the ion spray liquid chromatograph/mass spectrometer interface and the CZE column. The utility of the CZE/mass spectrometry union is demonstrated by its application to the separation of acid pesticides, sulfonated azo dyes and a tryptic digest of recombinant bovine somatotropin by CZE and detection by mass spectrometry and tandem mass spectrometry. Mass spectrometric detection was carried out in both positive and negative ion modes. Separation efficiencies are shown ranging from 50 000 to 300 000 theoretical plates with peak asymmetries of 1.2–1.8 for the components separated in the tryptic digest.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/bms.1200180932

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 180

Metadata

Authors
Lee, E. D., Mück, W., Henion, J. D., & Covey, T. R.
Venue
Biological Mass Spectrometry
Publisher
Wiley
Published
1989-09
Volume
18
Issue
9
Pages
844-850
ISSN
  • 1076-5174 (ISSN-L)
  • 0887-6134
  • 1096-9888
OpenAlex
W4243804942
Cited by
180
References
0
FWCI
10.00
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Liquid junction coupling for capillary zone electrophoresis/ion spray mass spectrometry. https://app.cochat.ai/papers/10.1002/bms.1200180932
The paper
Lee, E. D., Mück, W., Henion, J. D., & Covey, T. R. (1989). Liquid junction coupling for capillary zone electrophoresis/ion spray mass spectrometry. Biological Mass Spectrometry. https://doi.org/10.1002/bms.1200180932

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.