Measurement of15N enrichment in multiple amino acids and urea in a single analysis by gas chromatography/mass spectrometry
The DOI matches its Crossref record.
Abstract
A precise and accurate procedure to measure the 15N isotopic enrichment of 18 common plasma amino acids and singly (15N1) and doubly (15N2) labeled urea in a single analysis by selected ion monitoring electron impact ionization gas chromatography/mass spectrometry analysis is presented. The choice of tert-butyldimethylsilyl derivatives allowed the enrichments in the amide and amino nitrogens of glutamine to be resolved. The ions monitored contained all the nitrogen atoms from the parent compounds except for arginine, which lost one guanidino nitrogen. Isotope ratios were determined with a coefficient of variation (within-assay precision) of 0.35% (range, 0.1-1.0%) on replicate measures averaged over all components; thus, the standard deviation associated with a nominal [m + 1]/[m + 0] isotope ratio of 0.2000 was 0.0007. The average error between measured and theoretical [m + 1]/[m + 0] isotope ratios was +0.0001 +/- 0.0086 for samples at natural abundance isotopic composition. The utility of the procedure is demonstrated by monitoring the incorporation of 15N into 18 plasma amino acids and urea during a 6 h oral administration of 15NH4Cl to a human volunteer. Highest levels of enrichment were achieved in arginine and urea, followed by glutamine. Approximately 80% of the label in glutamine was in the amino nitrogen. Excess 15N enrichment was observed in all plasma amino acids monitored with the exception of the essential amino acids phenylalanine, lysine and histidine. This method will facilitate the measurement of isotopic enrichment of multiple amino acids by a single analysis when it is necessary to monitor multiple stable-isotopically labeled amino acids in studies of amino acid and protein metabolic kinetics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Human ApoE isoforms differentially regulate brain amyloid-β peptide clearance
Castellano, J. M., Kim, J., Stewart, F. R., Jiang, H., DeMattos, R. B., Patterson, B. W., Fagan, A. M., Morris, J. C., Mawuenyega, K. G., Cruchaga, C., et al. (2011) · Science Translational Medicine · doi:10.1126/scitranslmed.3002156 · Cited by 1,242
Self-citationSiervo, M., Jackson, S. J., & Bluck, L. J. C. (2011) · Journal of Hypertension · doi:10.1097/hjh.0b013e3283487806 · Cited by 44
Basak, J. M., Kim, J., Pyatkivskyy, Y., Wildsmith, K. R., Jiang, H., Parsadanian, M., Patterson, B. W., Bateman, R. J., & Holtzman, D. M. (2012) · Molecular Neurodegeneration · doi:10.1186/1750-1326-7-14 · Cited by 30
Self-citation
Metadata
- Authors
- Patterson, B. W., Carraro, F., & Wolfe, R. R.
- Venue
- Biological Mass Spectrometry
- Publisher
- Wiley
- Published
- 1993-09
- Volume
- 22
- Issue
- 9
- Pages
- 518-523
- ISSN
- 1076-5174 (ISSN-L)
- 1052-9306
- 1096-9888
- OpenAlex
- W2047907055
- Cited by
- 83
- References
- 0
- FWCI
- 1.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.