Automated detection of intracranial large vessel occlusions using Viz.ai software: Experience in a large, integrated stroke network
Open accessThe DOI matches its Crossref record.
Abstract
Background and purpose: Endovascular thrombectomy is an evidence‐based treatment for large vessel occlusion (LVO) stroke. Commercially available artificial intelligence has been designed to detect the presence of an LVO on computed tomography angiogram (CTA). We compared Viz.ai‐LVO (San Francisco, CA, USA) to CTA interpretation by board‐certified neuroradiologists (NRs) in a large, integrated stroke network. Methods: From January 2021 to December 2021, we compared Viz.ai detection of an internal carotid artery (ICA) or middle cerebral artery first segment (MCA‐M1) occlusion to the gold standard of CTA interpretation by board‐certified NRs for all code stroke CTAs. On a monthly basis, sensitivity, specificity, accuracy, positive predictive value (PPV), and negative predictive value (NPV) were calculated. Trend analyses were conducted to evaluate for any improvement of LVO detection by the software over time. Results: 3851 patients met study inclusion criteria, of whom 220 (5.7%) had an ICA or MCA‐M1 occlusion per NR. Sensitivity and specificity were 78.2% (95% CI 72%–83%) and 97% (95% CI 96%–98%), respectively. PPV was 61% (95% CI 55%–67%), NPV 99% (95% CI 98%–99%), and accuracy was 95.9% (95% CI 95.3%–96.5%). Neither specificity or sensitivity improved over time in the trend analysis. Conclusions: Viz.ai‐LVO has high specificity and moderately high sensitivity to detect an ICA or proximal MCA occlusion. The software has the potential to streamline code stroke workflows and may be particularly impactful when emergency access to NRs or vascular neurologists is limited.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
AI revolutionizing industries worldwide: A comprehensive overview of its diverse applications
Rashid, A. B., & Kausik, M. A. K. (2024) · Hybrid Advances · doi:10.1016/j.hybadv.2024.100277 · Cited by 764
The current and future state of AI interpretation of medical images
Rajpurkar, P., & Lungren, M. P. (2023) · New England Journal of Medicine · doi:10.1056/nejmra2301725 · Cited by 443
Ethical Challenges and Opportunities in Applying Artificial Intelligence to Cardiovascular Medicine
Lewin, S., Chetty, R., Ihdayhid, A. R., & Dwivedi, G. (2024) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2024.06.029 · Cited by 36
Metadata
- Authors
- Karamchandani, R. R., Helms, A. M., Satyanarayana, S., Yang, H., Clemente, J. D., Defilipp, G., Strong, D., Rhoten, J. B., & Asimos, A. W.
- Venue
- Brain and Behavior
- Publisher
- Wiley
- Published
- 2022-12
- Volume
- 13
- Issue
- 1
- Pages
- e2808-e2808
- ISSN
- 2157-9032 (ISSN-L)
- 2162-3279
- OpenAlex
- W4310542497
- Cited by
- 58
- References
- 0
- FWCI
- 6.74
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Automated detection of intracranial large vessel occlusions using Viz.ai software: Experience in a large, integrated stroke network. https://app.cochat.ai/papers/10.1002/brb3.2808
- The paper
- Karamchandani, R. R., Helms, A. M., Satyanarayana, S., Yang, H., Clemente, J. D., Defilipp, G., Strong, D., Rhoten, J. B., & Asimos, A. W. (2023). Automated detection of intracranial large vessel occlusions using Viz.ai software: Experience in a large, integrated stroke network. Brain and Behavior. https://doi.org/10.1002/brb3.2808
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.