Cited by 12

Accurate and Rapid Protein Concentration Measurement of in‐Process, High Concentration Protein Pools

McKechnie, William S., Tugcu, Nihal, Kandula, Sunitha·2018·Biotechnology Progress

Abstract

Protein concentration is a critical product quality attribute and required for any therapeutic protein. Many commercial and investigational new biologics are now formulated at high concentrations (>100 mg/ml) to achieve successful subcutaneous administration. Assaying protein concentration in high concentration formulations poses a challenge, as traditional absorption spectroscopy and UPLC/HPLC (ultra/high performance liquid chromatography) assays cannot accurately measure such high concentrations without further solution manipulation. However, recent advances in UV/vis technology have led to the creation of instruments that measure samples at relatively short (<1 cm) path lengths, which would allow them to accurately measure high concentration protein samples in accordance with Beer Lambert Law principles. In this research, samples of five different proteins at concentrations ranging from 0.15 to 242 mg/ml (corresponding to OD280 vales of 0.15–315 AU) were measured on two different instruments employing different techniques of low path length UV/vis measurements. In order for the techniques to meet MSD's acceptance criteria for release assays, measurements were required to be accurate to within 10% of a reference measurement (performed on a traditional UV/vis spectrophotometer) and to be precise within 5% CV. The results show that using a technique known as slope spectroscopy, it is possible to measure OD280 from 0.5 to 315 AU with <7% error relative to the reference measurement. If instead measurements are taken using an instrument utilizing a single, small path length, it is possible to measure absorbances from 0.2 to ~75 AU with <7% error. This article concludes that the slope spectroscopy technique performed within the acceptance criteria across the full range of measured absorbances and that the single, short path length measurement performed within the acceptance criteria up to 75 AU.

Integrity signals

Registry

Crossref · 10.1002/btpr.2695

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Accurate measurements of protein concentrations can be made with VPE even with high-concentration proteins without requiring dilutions.

    “Accurate measurements of protein concentrations can be made with VPE, even with high‐concentration proteins without requiring dilutions [81].”

Cited by

Sorted by citations

Authors
McKechnie, W. S., Tugcu, N., & Kandula, S.
Affiliations
Downstream Process Development and Engineering Biologics and Vaccines MRL, Kenilworth, New Jersey
Venue
Biotechnology Progress
Publisher
Wiley
Published
2018-09
Volume
34
Issue
5
Pages
1234-1241
ISSN
  • 8756-7938
  • 1520-6033
Cited by
12
References
0
Language
en

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review