CoChat

Anatomical and mechanical relationship between the proximal attachment of adductor longus and the distal rectus sheath

Norton‐old, Kimberley J., Schache, Anthony G., Barker, Priscilla J., Clark, Ross A., Harrison, Simon M., Briggs, Christopher A. · 2013 · Clinical Anatomy
Cited by 76

The DOI matches its Crossref record.

Abstract

The objectives of this study were to investigate the anatomical relationship between the proximal adductor longus (AL) and rectus abdominis muscles and to determine whether unilateral loading of AL results in strain transmission across the anterior pubic symphysis to the contralateral distal rectus sheath. Bilateral dissections were conducted on 10 embalmed cadavers. Strain transfer across the pubic symphysis was examined on seven of these cadavers. An AL contraction was simulated by applying a controlled load in the direction of its proximal tendinous fibers, and the resultant strain in the contralateral distal rectus sheath was measured using a foil‐type surface mounted microstrain gage. Adductor longus attached to the antero‐inferior aspect of the pubis. In 18 of the 20 limbs, the proximal attachment of AL was tendinous on its superficial surface and muscular on its deep surface. The proximal AL tendon was found in most instances to have secondary communications with structures such as the contralateral distal rectus sheath, pubic symphysis anterior capsule, ilio‐inguinal ligament, and contralateral proximal AL tendon. Despite these consistent anatomical observations, strain measured in the contralateral distal rectus sheath upon unilateral loading of the proximal AL varied considerably between cadavers. Measured strain had an average ± 1SD of 0.23 ± 0.43%. The proximal attachment of AL contributes to an anatomical pathway across the anterior pubic symphysis that is likely required to withstand the transmission of large forces during multidirectional athletic activities. This anatomical relationship may be a relevant factor in explaining the apparent vulnerability of the AL and rectus abdominis attachments to injury. Clin. Anat. 2013. © 2012 Wiley Periodicals, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/ca.22116

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 76

Metadata

Authors
Norton‐old, K. J., Schache, A. G., Barker, P. J., Clark, R. A., Harrison, S. M., & Briggs, C. A.
Venue
Clinical Anatomy
Publisher
Wiley
Published
2012-06-14
Volume
26
Issue
4
Pages
522-530
ISSN
  • 0897-3806 (ISSN-L)
  • 1098-2353
OpenAlex
W2135470851
Cited by
76
References
0
FWCI
2.71
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Anatomical and mechanical relationship between the proximal attachment of adductor longus and the distal rectus sheath. https://app.cochat.ai/papers/10.1002/ca.22116
The paper
Norton‐old, K. J., Schache, A. G., Barker, P. J., Clark, R. A., Harrison, S. M., & Briggs, C. A. (2013). Anatomical and mechanical relationship between the proximal attachment of adductor longus and the distal rectus sheath. Clinical Anatomy. https://doi.org/10.1002/ca.22116

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.