Cardiac catheterization in morbidly obese patients
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The safety and findings of cardiac catheterization and coronary angiography in morbidly obese patients with suspected coronary heart disease (CHD) have not been fully examined in the modern era. From a database of 4,978 patients undergoing diagnostic cardiac catheterization, we identified 110 with morbid obesity (body mass ≥ 145 kg and body mass index ≥ 40 kg/m 2). Relative to all the other patients in this database, morbidly obese patients had a lower prevalence of CHD (45% vs. 72%; P < 0.05), reflecting a higher prevalence of false positive noninvasive tests. Overall, noninvasive tests were only 75% sensitive and 39% specific for CHD in this group. Use of radial access (66%) and femoral closure devices (24%) was much more frequent in the morbidly obese cohort. Complications were no more frequent in the morbidly obese group, with major (0 vs. 0.9%) and minor (4.7% vs. 3.5%) adverse outcomes being similar to the rest of the database. We conclude that cardiac catheterization using the radial artery or a femoral closure device is a safe and effective method of evaluating CHD in morbidly obese patients. In contrast, noninvasive testing is frequently not definitive and may be misleading. Cathet Cardiovasc Intervent 2002;56:174–177. © 2002 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cited by
Obesity and cardiovascular disease: a scientific statement from the American Heart Association
Powell-Wiley, T. M., Poirier, P., Burke, L. E., Després, J.-P., Gordon-Larsen, P., Lavie, C. J., Lear, S. A., Ndumele, C. E., Neeland, I. J., Sanders, P., et al. (2021) · Circulation · doi:10.1161/cir.0000000000000973 · Cited by 3,691
Poirier, P., Giles, T. D., Bray, G. A., Hong, Y., Stern, J. S., Pi-Sunyer, F. X., & Eckel, R. H. (2006) · Circulation · doi:10.1161/circulationaha.106.171016 · Cited by 3,165
Fihn, S. D., Gardin, J. M., Abrams, J., Berra, K., Blankenship, J. C., Dallas, A. P., Douglas, P. S., Foody, J. M., Gerber, T. C., Hinderliter, A. L., et al. (2012) · Circulation · doi:10.1161/cir.0b013e3182776f83 · Cited by 2,410
Fihn, S. D., Gardin, J. M., Abrams, J., Berra, K., Blankenship, J. C., Dallas, A. P., Douglas, P. S., Foody, J. M., Gerber, T. C., Hinderliter, A. L., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.07.013 · Cited by 1,555
Fihn, S. D., Gardin, J. M., Abrams, J., Berra, K., Blankenship, J. C., Dallas, A. P., Douglas, P. S., Foody, J. M., Gerber, T. C., Hinderliter, A. L., et al. (2012) · Circulation · doi:10.1161/cir.0b013e318277d6a0 · Cited by 845
Metadata
- Authors
- McNulty, P. H., Ettinger, S. M., Field, J. M., Gilchrist, I. C., Kozak, M., Chambers, C. E., & Gascho, J. A.
- Venue
- Catheterization and Cardiovascular Interventions
- Publisher
- Wiley
- Published
- 2002-05-24
- Volume
- 56
- Issue
- 2
- Pages
- 174-177
- ISSN
- 1522-1946 (ISSN-L)
- 1522-726X
- OpenAlex
- W2057189250
- Cited by
- 63
- References
- 1
- FWCI
- 1.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cardiac catheterization in morbidly obese patients. https://app.cochat.ai/papers/10.1002/ccd.10186
- The paper
- McNulty, P. H., Ettinger, S. M., Field, J. M., Gilchrist, I. C., Kozak, M., Chambers, C. E., & Gascho, J. A. (2002). Cardiac catheterization in morbidly obese patients. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.10186
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.