CoChat

Stenting of coarctation of the aorta

Cheatham, John P. · 2001 · Catheterization and Cardiovascular Interventions
Cited by 159

The DOI matches its Crossref record.

Abstract

The purpose of the present study was to assess the usefulness of balloon expandable Palmaz intravascular stents in the transcatheter treatment of children and young adults with native and recurrent coarctation of the aorta, and to develop an improved intravascular stent and balloon delivery catheter specifically developed for vascular obstructions associated with congenital heart disease, including coarctation of the aorta. Twenty‐one patients, 8 native and 13 recurrent coarctations, were successfully treated with the Palmaz stent. However, limitations and disadvantages in stent design and the single balloon delivery system were uncovered. Therefore, the NuMED CP stent and BIB delivery catheter were developed and used to treat 25 patients with native (17) and recurrent (8) coarctation successfully. Improvements in stent design and long‐term follow‐up using three‐dimensional spiral CT scan will be helpful in determining the role of transcatheter stent therapy for native and recurrent coarctation of the aorta. Cathet Cardiovasc Intervent 2001;54:112–125. © 2001 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/ccd.1249

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Cheatham, J. P.
Venue
Catheterization and Cardiovascular Interventions
Publisher
Wiley
Published
2001-08-27
Volume
54
Issue
1
Pages
112-125
ISSN
  • 1522-1946 (ISSN-L)
  • 1522-726X
OpenAlex
W2017477586
Cited by
159
References
0
FWCI
4.99
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.