Left atrial volume estimation by two‐dimensional echocardiography
The DOI matches its Crossref record.
Abstract
We examined 12 patients aged six months to 76 years by echocardiography to determine left atrial volume. The results were compared with angiographic left atrial volumes calculated by the biplane Simpson's rule method. Three two‐dimensional planes were used: precordial long axis, apical two‐chamber, and four‐chamber. Area outlines were traced using a light pen computational system providing single plane area length estimates of left atrial volume. The two apical left atrial outlines were combined, and Simpson's rule method was used to calculate left atrial volume. M‐mode echocardio‐grams performed on these patients were used to estimate left atrial volume. As the resuits of covariance analysis showed that there was no significant difference in the line of regression in systole and diastole, these data were pooled for subsequent comparison with angiography. The closest correlation with angiography was the biplane Simpson rule method with the echocardiographic left atrial volume (Y) = 1.0, angiographic volume (X) + 6.3 ml, r = 0.86. The single plane area length estimates also correlated well with angiography, but correction factors were required. M‐mode estimates of left atrial volume could only correlate to angiography using a power function y = 3.7 X 1.80, r = 0.69. We conclude that left atrial volume can be determined by two‐dimensional echocardiography and that this technique is superior to M‐mode echocardiography.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Lang, R. M., Badano, L. P., Mor-Avi, V., Afilalo, J., Armstrong, A., Ernande, L., Flachskampf, F. A., Foster, E., Goldstein, S. A., Kuznetsova, T., et al. (2015) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2014.10.003 · Cited by 12,362
Lang, R. M., Bierig, M., Devereux, R. B., Flachskampf, F. A., Foster, E., Pellikka, P. A., Picard, M. H., Roman, M. J., Seward, J., Shanewise, J. S., et al. (2005) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2005.10.005 · Cited by 11,318
“However, this method has proven to be inferior to other volume techniques.(109,111,117) LA volumes are best calculated using either an ellipsoid model or Simpson’s rule.”
MethodInfluentialLang, R. M., Badano, L. P., Mor-Avi, V., Afilalo, J., Armstrong, A., Ernande, L., Flachskampf, F. A., Foster, E., Goldstein, S. A., Kuznetsova, T., et al. (2015) · European Heart Journal – Cardiovascular Imaging · doi:10.1093/ehjci/jev014 · Cited by 8,361
Recommendations for chamber quantification☆
LANG, R., BIERIG, M., DEVEREUX, R., FLACHSKAMPF, F., FOSTER, E., PELLIKKA, P., PICARD, M., ROMAN, M., SEWARD, J., & SHANEWISE, J. (2006) · European Journal of Echocardiography · doi:10.1016/j.euje.2005.12.014 · Cited by 3,571
Lopez, L., Colan, S. D., Frommelt, P. C., Ensing, G. J., Kendall, K., Younoszai, A. K., Lai, W. W., & Geva, T. (2010) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2010.03.019 · Cited by 1,553
Metadata
- Authors
- Schabelman, S., Schiller, N. B., Silverman, N. H., & Ports, T. A.
- Venue
- Catheterization and Cardiovascular Diagnosis
- Publisher
- Wiley
- Published
- 1981-01
- Volume
- 7
- Issue
- 2
- Pages
- 165-178
- ISSN
- 0098-6569 (ISSN-L)
- 1097-0304
- OpenAlex
- W2073411378
- Cited by
- 134
- References
- 0
- FWCI
- 3.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Left atrial volume estimation by two‐dimensional echocardiography. https://app.cochat.ai/papers/10.1002/ccd.1810070206
- The paper
- Schabelman, S., Schiller, N. B., Silverman, N. H., & Ports, T. A. (1981). Left atrial volume estimation by two‐dimensional echocardiography. Catheterization and Cardiovascular Diagnosis. https://doi.org/10.1002/ccd.1810070206
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.