Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 226

The DOI matches its Crossref record.

Use of a conductance (volume) catheter and transient inferior vena caval occlusion for rapid determination of pressure‐volume relationships in man

Kass, David A., Md, Mark Midei, Phd, Willard Graves, Brinker Fsca, Jeffrey A. , Md, Maughan, W. Lowell·1988·Catheterization and Cardiovascular Diagnosis

Abstract

Determination of left ventricular pressure‐volume relationships in situ ideally requires both a method for easy measurement of multiple pressure‐volume loops and a rapid and reversible means of altering load. We report a technique, previously used in animals, that combines conductance catheter volumes and rapid inferior vena caval occlusion to permit routine measurement of calibrated P‐V relationships in man for the first time. An 8F volume catheter with a 3F micromanometer tipped pressure catheter placed through its lumen was advanced to the left ventricular apex through a femoral artery. A thermodilution output catheter was placed through a 9F femoral venous sheath and later replaced with an IVC balloon occlusion catheter, through which a 2.5F bipolar wire was advanced for atrial pacing. A specialized data system facilitated collection, editing, and data analysis at the time of cardiac catheterization. Absolute volume calibration required cardiac output measurement and injection of hypertonic saline. IVC occlusion decreased peak left ventricular pressure by 42 ± 17 (SD) (P < .001) mm Hg in 15 patients. Endsystolic pressure‐volume relationships (ESPVR) were determined with 5–8 cardiac cycles with an average of r 2 of 0.94 ± 0.05 and were generally reproducible. The slope of the ESPVR demonstrated consistency among a group of normal patients (n = 6), and was significantly lower than the slope derived from a group of patients with ventricular hypertrophy (n = 9). We conclude that left ventricular pressure‐volume relationships can be easily and repeatedly determined as part of a routine cardiac catheterization in man.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/ccd.1810150314

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 226

Metadata

Authors
Kass, D. A., Md, M. M., Phd, W. G., Brinker Fsca, J. A., & Maughan, W. L.
Venue
Catheterization and Cardiovascular Diagnosis
Publisher
Wiley
Published
1988-01
Volume
15
Issue
3
Pages
192-202
ISSN
  • 0098-6569 (ISSN-L)
  • 1097-0304
OpenAlex
W1963771304
Cited by
226
References
0
FWCI
5.15
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Use of a conductance (volume) catheter and transient inferior vena caval occlusion for rapid determination of pressure‐volume relationships in man. https://app.cochat.ai/papers/10.1002/ccd.1810150314
The paper
Kass, D. A., Md, M. M., Phd, W. G., Brinker Fsca, J. A., & Maughan, W. L. (1988). Use of a conductance (volume) catheter and transient inferior vena caval occlusion for rapid determination of pressure‐volume relationships in man. Catheterization and Cardiovascular Diagnosis. https://doi.org/10.1002/ccd.1810150314

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.