Carotid stenting with distal protection in high surgical risk patients: The BEACH trial 30 day results

White, Christopher J., Iyer, Sriram S., Hopkins, L. Nelson, Katzen, Barry T., Russell, Mary E.·2006·Catheterization and Cardiovascular Interventions

Abstract

Background: The BEACH trial evaluated the outcomes of carotid artery stent placement with distal emboli protection, using the Carotid Wallstent® and the FilterWire EX®/EZ TM, in patients at high surgical risk for carotid endarterectomy (CEA). Methods: We enrolled 747 patients at high surgical risk for CEA due to prespecified anatomical criteria and/or medical comorbidities. The trial included both symptomatic (>50% carotid artery stenosis) as well as asymptomatic (>80% carotid artery stenosis) high surgical risk patients. Three groups of patients were included in the trial. The Roll‐in (R) group (n = 189/747, [25%]) included up to nine patients per site for familiarization of the device and protocol; the Pivotal (P) group (n = 480/747, [65%]) was intended for presentation to the FDA for consideration of device approval; and a Bilateral (B) registry group (n = 78/747, [10%]) was included because of the need to treat patients with bilateral carotid artery disease. In the 480 Pivotal patients, anatomic criteria represented the most frequent high‐risk surgical category for enrollment (58.8%), followed by prior CEA (34.2%), multivessel (≥2) coronary artery disease (21.7%), and contralateral carotid occlusion (18.1%). Results: The technical success rate for stent deployment and FilterWire EX/EZ deployment and retrieval was 98.2%. The mean postprocedure angiographic diameter stenosis in the Pivotal group was reduced to 10.8%, while the overall procedure success rate (<50% residual diameter stenosis) after stent deployment was 98%. The 30 day composite major adverse event (MAE) rate for the entire cohort of 747 patients (i.e. inclusive of all 3 groups) was 5.8% (all death = 1.5%, all stroke = 4.4%, and all myocardial infarction (MI) = 1.0%). In subgroup analysis, there was no significant difference in the MAE rate between the three groups (P = 5.8%, R = 6.9%, B = 2.6%, P = 0.42). Conclusion: The similarity in periprocedural event rates for the Pivotal and Roll‐in groups suggests a flat learning curve for experienced operators using this carotid stent system. The similarity in event rates for the Bilateral group, when compared with the Roll‐in and Pivotal groups, suggests that staged sequential treatment of bilateral stenoses may be performed at the same risk as for unilateral lesions. The 30‐day safety of this stent and distal emboli protection system is encouraging and compares favorably with other carotid stent trials in high surgical risk patients. © 2006 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/ccd.20689

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 244

Metadata

Authors
White, C. J., Iyer, S. S., Hopkins, L. N., Katzen, B. T., & Russell, M. E.
Venue
Catheterization and Cardiovascular Interventions
Publisher
Wiley
Published
2006-03-20
Volume
67
Issue
4
Pages
503-512
ISSN
  • 1522-1946 (ISSN-L)
  • 1522-726X
OpenAlex
W2147035197
Cited by
244
References
1
FWCI
28.71
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Carotid stenting with distal protection in high surgical risk patients: The BEACH trial 30 day results. https://app.cochat.ai/papers/10.1002/ccd.20689
The paper
White, C. J., Iyer, S. S., Hopkins, L. N., Katzen, B. T., & Russell, M. E. (2006). Carotid stenting with distal protection in high surgical risk patients: The BEACH trial 30 day results. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.20689

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.