Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 255

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Procedural results and acute complications in stenting native and recurrent coarctation of the aorta in patients over 4 years of age: A multi‐institutional study

Forbes, Thomas J., Garekar, Swati, Amin, Zahid, Zahn, Evan M., Nykanen, David, Moore, Phillip, Qureshi, Shakeel A., Cheatham, John P., Ebeid, Makram R., Hijazi, Ziyad M., Sandhu, Satinder, Hagler, Donald J., Sievert, Horst, Fagan, Thomas E., Ringewald, Jeremy, Du, Wei, Tang, Liwen, Wax, David F., Rhodes, John, Johnston, Troy A., Jones, Thomas K., Turner, Daniel R., Pedra, Carlos A.C., Hellenbrand, William E.·2007·Catheterization and Cardiovascular Interventions

Abstract

Background: We report a multi‐institutional experience with intravascular stenting (IS) for treatment of coarctation of the aorta. Methods and Results: Data was collected retrospectively by review of medical records from 17 institutions. The data was broken down to prior to 2002 and after 2002 for further analysis. A total of 565 procedures were performed with a median age of 15 years (mean = 18.1 years). Successful reduction in the post stent gradient (<20 mm Hg) or increase in post stent coarctation to descending aorta (DAo) ratio of >0.8 was achieved in 97.9% of procedures. There was significant improvement (P < 0.01) in pre versus post stent coarctation dimensions (7.4 mm ± 3.0 mm vs. 14.3 ± 3.2mm), systolic gradient (31.6 mm Hg ± 16.0 mm Hg vs. 2.7 mm Hg ± 4.2 mm Hg) and ratio of the coarctation segment to the DAo (0.43 ± 0.17 vs. 0.85 ± 0.15). Acute complications were encountered in 81/565 (14.3%) procedures. There were two procedure related deaths. Aortic wall complications included: aneurysm formation (n = 6), intimal tears (n = 8), and dissections (n = 9). The risk of aortic dissection increased significantly in patients over the age of 40 years. Technical complications included stent migration (n = 28), and balloon rupture (n = 13). Peripheral vascular complications included cerebral vascular accidents (CVA) (n = 4), peripheral emboli (n = 1), and significant access arterial injury (n = 13). Older age was significantly associated with occurrence of CVAs. A significant decrease in the technical complication rate from 16.3% to 6.1% (P < 0.001) was observed in procedures performed after January 2002. Conclusions: Stent placement for coarctation of aorta is an effective treatment option, though it remains a technically challenging procedure. Technical and aortic complications have decreased over the past 3 years due to, in part, improvement in balloon and stent design. Improvement in our ability to assess aortic wall compliance is essential prior to placement of ISs in older patients with coarctation of the aorta. © 2007 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/ccd.21164

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 255

Metadata

Authors
Forbes, T. J., Garekar, S., Amin, Z., Zahn, E. M., Nykanen, D., Moore, P., Qureshi, S. A., Cheatham, J. P., Ebeid, M. R., Hijazi, Z. M., Sandhu, S., Hagler, D. J., Sievert, H., Fagan, T. E., Ringewald, J., Du, W., Tang, L., Wax, D. F., Rhodes, J., Johnston, T. A., Jones, T. K., Turner, D. R., Pedra, C. A. C., & Hellenbrand, W. E.
Venue
Catheterization and Cardiovascular Interventions
Publisher
Wiley
Published
2007-07-16
Volume
70
Issue
2
Pages
276-285
ISSN
  • 1522-1946 (ISSN-L)
  • 1522-726X
OpenAlex
W1982736921
Cited by
255
References
1
FWCI
9.42
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.