The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Transcatheter aortic valve implantation: Lessons from the learning curve of the first 270 high‐risk patients
Abstract
Background: Transcatheter aortic valve implantation (TAVI) is a rapidly evolving strategy for therapy of aortic stenosis. We describe the effect of the learning curve from the first 270 high‐risk patients in Vancouver, Canada. Methods: Patients underwent TAVI by transfemoral (63%) or transapical (37%) routes using balloon expandable valves. The experience was divided into the first half (FH, patients 1–135) and second half (SH, patients 136–270). Results: The mean age was 83.2 ± 8 years (FH 83 ± 12 vs. SH 81 ± 7 years, P = 0.12). The mean Society of Thoracic Surgeons Score (STS) was 9.5% ± 5.2%‐ FH 10.5 vs. SH 8.5% (P = 0.01). The overall procedural success rate in the FH was 92.6%, improving to 97.8% in the SH (P = 0.05). The transfemoral procedural success improved—FH 89.3% to SH 98.8% (P = 0.01). The transapical procedural success remained high—FH 98.0% to SH 96.1% (P = 0.53). The overall 30‐day mortality was 9.6%, improving from FH 13.3% to SH 5.9% (P = 0.04). In the transfemoral cases, 30‐day mortality decreased by 56% [10.7–4.7%, P = 0.14], and similarly in transapical cases [17.6–7.8%, P = 0.14]. In‐hospital stroke occurred in 3.3% (FH 3.7% vs. SH 2.9%, P = 0.74). The overall need for a new permanent pacemaker was 5.9% (FH 5.9% vs. SH 5.9%, P = 1). The overall major vascular injury rate was 6.7% (FH 8.1% vs. SH 5.2%, P = 0.33). The overall incidence of coronary vessel occlusion was 1.1% (FH 1.5 % vs. SH 0.7%, P = 0.56). Device embolization or failure to cross the valve was rare and largely seen in the FH only. Procedural experience (>135 procedures) was an independent predictor of 30‐day survival (HR: 6.7, 95% CI: 1.2–18.1, P = 0.03). Conclusion: TAVI outcomes improve with experience and device development. While overall complication rates are low, scope remains to further reduce procedural adverse events.© 2011 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Levey, A. S., Bosch, J. P., Lewis, J. B., Greene, T., Rogers, N., Roth, D., & for the Modification of Diet in Renal Disease Study Group* (1999) · Annals of Internal Medicine · doi:10.7326/0003-4819-130-6-199903160-00002 · Cited by 15,079
Transcatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo Surgery
Leon, M. B., Smith, C. R., Mack, M., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1008232 · Cited by 7,205
Self-citation
Cited by
Two-Year Outcomes after Transcatheter or Surgical Aortic-Valve Replacement
Kodali, S. K., Williams, M. R., Smith, C. R., Svensson, L. G., Webb, J. G., Makkar, R. R., Fontana, G. P., Dewey, T. M., Thourani, V. H., Pichard, A. D., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1200384 · Cited by 2,282
Self-citation2012 ACCF/AATS/SCAI/STS Expert Consensus Document on Transcatheter Aortic Valve Replacement
Holmes, D. R., Mack, M. J., Kaul, S., Agnihotri, A., Alexander, K. P., Bailey, S. R., Calhoon, J. H., Carabello, B. A., Desai, M. Y., Edwards, F. H., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.01.001 · Cited by 749
Vascular Complications After Transcatheter Aortic Valve Replacement
Généreux, P., Webb, J. G., Svensson, L. G., Kodali, S. K., Satler, L. F., Fearon, W. F., Davidson, C. J., Eisenhauer, A. C., Makkar, R. R., Bergman, G. W., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.07.003 · Cited by 518
Self-citationBinder, R. K., Webb, J. G., Willson, A. B., Urena, M., Hansson, N. C., Norgaard, B. L., Pibarot, P., Barbanti, M., Larose, E., Freeman, M., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.04.036 · Cited by 335
Self-citationTranscatheter aortic valve implantation: current and future approaches
Rodés-Cabau, J. (2012) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2011.164 · Cited by 306
Khatri, P. J., Webb, J. G., Rodés-Cabau, J., Fremes, S. E., Ruel, M., Lau, K., Guo, H., Wijeysundera, H. C., & Ko, D. T. (2013) · Annals of Internal Medicine · doi:10.7326/0003-4819-158-1-201301010-00007 · Cited by 273
Self-citation
Metadata
- Authors
- Gurvitch, R., Tay, E. L., Wijesinghe, N., Ye, J., Nietlispach, F., Wood, D. A., Lichtenstein, S., Cheung, A., & Webb, J. G.
- Venue
- Catheterization and Cardiovascular Interventions
- Publisher
- Wiley
- Published
- 2011-06-07
- Volume
- 78
- Issue
- 7
- Pages
- 977-984
- ISSN
- 1522-1946 (ISSN-L)
- 1522-726X
- OpenAlex
- W1489391104
- Cited by
- 164
- References
- 2
- FWCI
- 17.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.