CoChat

Clinical outcome of transcatheter aortic valve implantation in patients with low‐flow, low gradient aortic stenosis

Gotzmann, Michael, Lindstaedt, Michael, Bojara, Waldemar, Ewers, Aydan, Mügge, Andreas · 2012 · Catheterization and Cardiovascular Interventions
Cited by 58

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Background: Low‐flow, low‐gradient aortic stenosis is associated with relevant postoperative mortality whereas conservative management results in dismal prognosis. We present the initial experience of low‐flow, low‐gradient aortic stenosis treated with transcatheter aortic valve implantation (TAVI). Methods: From June 2008 to December 2010 167 consecutive patients with native severe aortic stenosis and an excessive operative risk underwent TAVI. Of these, 15 patients presented with low‐flow, low‐gradient aortic stenosis (aortic valve area < 1 cm 2, left ventricular (LV) ejection fraction < 40%, aortic mean gradient < 40 mm Hg). The CoreValve prosthesis 18‐F‐generation (Medtronic, Minneapolis, Minnesota) was inserted retrograde. Clinical follow‐up and echocardiography were performed 6 months after procedure. Results: Patients with low‐flow, low‐gradient aortic stenosis (mean LV ejection fraction 32 ± 6%, mean aortic gradient 27 ± 7 mm Hg) had higher all‐cause mortality 6 months after TAVI compared to patients without low‐flow, low‐gradient aortic stenosis (33% vs. 13%, P = 0.037). In the surviving 10 patients with low‐flow, low‐gradient aortic stenosis, LV ejection fraction increased (34 ± 6% before vs. 46 ± 11% 6 months after TAVI, p = 0.005) and more distance covered in the 6‐minute walk test (218 ± 102 meters before vs. 288 ± 129 meters 6 months after TAVI, p = 0.038). Conclusion: Our study suggests that TAVI is feasible in patients with severe co‐morbidities and low‐flow, low‐gradient aortic stenosis. Within the first 6 months after treatment all‐cause mortality was considerable high, but the surviving patients showed symptomatic benefit and significant improvement of myocardial function and exercise capacity. © 2011 Wiley Periodicals, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/ccd.23240

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 58

Metadata

Authors
Gotzmann, M., Lindstaedt, M., Bojara, W., Ewers, A., & Mügge, A.
Venue
Catheterization and Cardiovascular Interventions
Publisher
Wiley
Published
2011-08-05
Volume
79
Issue
5
Pages
693-701
ISSN
  • 1522-1946 (ISSN-L)
  • 1522-726X
OpenAlex
W2012690369
Cited by
58
References
4
FWCI
4.92
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.