The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
A Sensitive and Selective Fluorescent Thiol Probe in Water Based on the Conjugate 1,4‐Addition of Thiols to α,β‐Unsaturated Ketones
Open accessAbstract
Shedding light on thiol detection: A compound (see scheme) was developed as a novel, highly sensitive and selective fluorescent thiol probe, which also features suitable water solubility, functions rapidly under neutral conditions, and has excitation and emission in the visible region. Thus, it may be useful for potential biological applications.magnified image Compound 1 was designed and synthesized as a new fluorescent thiol probe. Probe 1 was constructed on the basis of the conjugate 1,4‐addition of thiols to α,β‐unsaturated ketones. Notably, probe 1 has suitable water solubility, which allows the sensing assay to be performed in water. Probe 1 is highly sensitive for thiols with a 211‐fold fluorescence dynamic range and a low detection limit of 9.25×10−7 M. The major features of probe 1 also include a high selectivity for thiols over other relevant biological species, excitation and emission in the visible region, rapid functioning at pH 7.4, and a good linear relationship between the fluorescence signal and the thiol concentration. Accordingly, these desirable characteristics may render probe 1 as potentially useful for biological applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Plasma Homocysteine as a Risk Factor for Dementia and Alzheimer's Disease
Seshadri, S., Beiser, A., Selhub, J., Jacques, P. F., Rosenberg, I. H., D'Agostino, R. B., Wilson, P. W. F., & Wolf, P. A. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa011613 · Cited by 3,237
Homocysteine and Cardiovascular Disease
Refsum, H., Ueland, P. M., Nygård, O., & Vollset, S. E. (1998) · Annual Review of Medicine · doi:10.1146/annurev.med.49.1.31 · Cited by 2,180
Cited by
Fluorescent and colorimetric probes for detection of thiols
Chen, X., Zhou, Y., Peng, X., & Yoon, J. (2010) · Chemical Society Reviews · doi:10.1039/b925092a · Cited by 1,580
Yang, X., Guo, Y., & Strongin, R. M. (2011) · Angewandte Chemie International Edition · doi:10.1002/anie.201103759 · Cited by 658
Thiol-addition reactions and their applications in thiol recognition
Yin, C., Huo, F., Zhang, J., Martínez-Máñez, R., Yang, Y., Lv, H., & Li, S. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60055f · Cited by 554
Ratiometric Detection of Mitochondrial Thiols with a Two-Photon Fluorescent Probe
Lim, C. S., Masanta, G., Kim, H. J., Han, J. H., Kim, H. M., & Cho, B. R. (2011) · Journal of the American Chemical Society · doi:10.1021/ja205081s · Cited by 365
Li, H., Fan, J., Wang, J., Tian, M., Du, J., Sun, S., Sun, P., & Peng, X. (2009) · Chemical Communications · doi:10.1039/b907511a · Cited by 339
Metadata
- Authors
- Lin, W., Yuan, L., Cao, Z., Feng, Y., & Long, L.
- Venue
- Chemistry – A European Journal
- Publisher
- Wiley
- Published
- 2009-05-04
- Volume
- 15
- Issue
- 20
- Pages
- 5096-5103
- ISSN
- 0947-6539 (ISSN-L)
- 1521-3765
- OpenAlex
- W2040382777
- Cited by
- 367
- References
- 2
- FWCI
- 13.63
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Sensitive and Selective Fluorescent Thiol Probe in Water Based on the Conjugate 1,4‐Addition of Thiols to α,β‐Unsaturated Ketones. https://app.cochat.ai/papers/10.1002/chem.200802751
- The paper
- Lin, W., Yuan, L., Cao, Z., Feng, Y., & Long, L. (2009). A Sensitive and Selective Fluorescent Thiol Probe in Water Based on the Conjugate 1,4‐Addition of Thiols to α,β‐Unsaturated Ketones. Chemistry – A European Journal. https://doi.org/10.1002/chem.200802751
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.