Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 158

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Simple Biosensor with High Selectivity and Sensitivity: Thiol‐Specific Biomolecular Probing and Intracellular Imaging by AIE Fluorogen on a TLC Plate through a Thiol–Ene Click Mechanism

Open access
Liu, Yang, Yu, Yong, Lam, Jacky W. Y., Hong, Yuning, Faisal, Mahtab, Yuan, Wang Zhang, Tang, Ben Zhong·2010·Chemistry – A European Journal

Abstract

A handy, specific, sensitive bioprobe has been developed. Tetraphenylethene (TPE) was functionalized by a maleimide (MI) group, giving a TPE‐MI adduct that was nonemissive in both solution and the solid state. It was readily transformed into a fluorogen showing an aggregation‐induced emission (AIE) property by the click addition of thiol to its MI pendant. The click reaction and the AIE effect enabled TPE‐MI to function as a thiol‐specific bioprobe in the solid state. Thus, the spot of TPE‐MI on a TLC plate became emissive when it had been exposed to L‐cysteine, an amino acid containing a thiol group, but remained nonemissive when exposed to other amino acids that lack free thiol units. The thiol‐activated emission was rapid and strong, readily detected by the naked eye at an analyte concentration as low as approximately 1 ppb, thanks to the “lighting up” nature of the bioprobing process. Similarly, the emission of TPE‐MI was turned on only by the proteins containing free thiol units, such as glutathione. Clear fluorescence images were taken when living cells were stained by using TPE‐MI as a visualization agent, affording a facile fluorescent maker for mapping the distribution of thiol species in cellular systems.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/chem.200902505

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 158

Metadata

Authors
Liu, Y., Yu, Y., Lam, J. W. Y., Hong, Y., Faisal, M., Yuan, W. Z., & Tang, B. Z.
Venue
Chemistry – A European Journal
Publisher
Wiley
Published
2010-07-19
Volume
16
Issue
28
Pages
8433-8438
ISSN
  • 0947-6539 (ISSN-L)
  • 1521-3765
OpenAlex
W2099527142
Cited by
158
References
2
FWCI
6.33
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Simple Biosensor with High Selectivity and Sensitivity: Thiol‐Specific Biomolecular Probing and Intracellular Imaging by AIE Fluorogen on a TLC Plate through a Thiol–Ene Click Mechanism. https://app.cochat.ai/papers/10.1002/chem.200902505
The paper
Liu, Y., Yu, Y., Lam, J. W. Y., Hong, Y., Faisal, M., Yuan, W. Z., & Tang, B. Z. (2010). Simple Biosensor with High Selectivity and Sensitivity: Thiol‐Specific Biomolecular Probing and Intracellular Imaging by AIE Fluorogen on a TLC Plate through a Thiol–Ene Click Mechanism. Chemistry – A European Journal. https://doi.org/10.1002/chem.200902505

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.