The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Simple Biosensor with High Selectivity and Sensitivity: Thiol‐Specific Biomolecular Probing and Intracellular Imaging by AIE Fluorogen on a TLC Plate through a Thiol–Ene Click Mechanism
Open accessAbstract
A handy, specific, sensitive bioprobe has been developed. Tetraphenylethene (TPE) was functionalized by a maleimide (MI) group, giving a TPE‐MI adduct that was nonemissive in both solution and the solid state. It was readily transformed into a fluorogen showing an aggregation‐induced emission (AIE) property by the click addition of thiol to its MI pendant. The click reaction and the AIE effect enabled TPE‐MI to function as a thiol‐specific bioprobe in the solid state. Thus, the spot of TPE‐MI on a TLC plate became emissive when it had been exposed to L‐cysteine, an amino acid containing a thiol group, but remained nonemissive when exposed to other amino acids that lack free thiol units. The thiol‐activated emission was rapid and strong, readily detected by the naked eye at an analyte concentration as low as approximately 1 ppb, thanks to the “lighting up” nature of the bioprobing process. Similarly, the emission of TPE‐MI was turned on only by the proteins containing free thiol units, such as glutathione. Clear fluorescence images were taken when living cells were stained by using TPE‐MI as a visualization agent, affording a facile fluorescent maker for mapping the distribution of thiol species in cellular systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Aggregation-induced emission of 1-methyl-1,2,3,4,5-pentaphenylsilole
Luo, J., Xie, Z., Lam, J. W. Y., Cheng, L., Tang, B. Z., Chen, H., Qiu, C., Kwok, H. S., Zhan, X., Liu, Y., et al. (2001) · Chemical Communications · doi:10.1039/b105159h · Cited by 8,358
Self-citationPlasma Homocysteine as a Risk Factor for Dementia and Alzheimer's Disease
Seshadri, S., Beiser, A., Selhub, J., Jacques, P. F., Rosenberg, I. H., D'Agostino, R. B., Wilson, P. W. F., & Wolf, P. A. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa011613 · Cited by 3,237
Cited by
Aggregation-Induced Emission: Together We Shine, United We Soar!
Mei, J., Leung, N. L. C., Kwok, R. T. K., Lam, J. W. Y., & Tang, B. Z. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00263 · Cited by 8,270
Self-citationHong, Y., Lam, J. W. Y., & Tang, B. Z. (2011) · Chemical Society Reviews · doi:10.1039/c1cs15113d · Cited by 6,363
Self-citationNew sensing mechanisms for design of fluorescent chemosensors emerging in recent years
Wu, J., Liu, W., Ge, J., Zhang, H., & Wang, P. (2011) · Chemical Society Reviews · doi:10.1039/c0cs00224k · Cited by 1,858
Biosensing by luminogens with aggregation-induced emission characteristics
Kwok, R. T. K., Leung, C. W. T., Lam, J. W. Y., & Tang, B. Z. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00325j · Cited by 1,296
Self-citationZhao, Z., Lam, J. W. Y., & Tang, B. Z. (2012) · Journal of Materials Chemistry · doi:10.1039/c2jm31949g · Cited by 867
Self-citation
Metadata
- Authors
- Liu, Y., Yu, Y., Lam, J. W. Y., Hong, Y., Faisal, M., Yuan, W. Z., & Tang, B. Z.
- Venue
- Chemistry – A European Journal
- Publisher
- Wiley
- Published
- 2010-07-19
- Volume
- 16
- Issue
- 28
- Pages
- 8433-8438
- ISSN
- 0947-6539 (ISSN-L)
- 1521-3765
- OpenAlex
- W2099527142
- Cited by
- 158
- References
- 2
- FWCI
- 6.33
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Simple Biosensor with High Selectivity and Sensitivity: Thiol‐Specific Biomolecular Probing and Intracellular Imaging by AIE Fluorogen on a TLC Plate through a Thiol–Ene Click Mechanism. https://app.cochat.ai/papers/10.1002/chem.200902505
- The paper
- Liu, Y., Yu, Y., Lam, J. W. Y., Hong, Y., Faisal, M., Yuan, W. Z., & Tang, B. Z. (2010). Simple Biosensor with High Selectivity and Sensitivity: Thiol‐Specific Biomolecular Probing and Intracellular Imaging by AIE Fluorogen on a TLC Plate through a Thiol–Ene Click Mechanism. Chemistry – A European Journal. https://doi.org/10.1002/chem.200902505
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.