The DOI matches its Crossref record.
Dipyrenylcalix[4]arene—A Fluorescence‐Based Chemosensor for Trinitroaromatic Explosives
Abstract
A new chemosensor‐based approach to the detection of nitroaromatics is described. It involves the analyte‐induced quenching of excimer emission of a dipyrenyl calix[4]arene (L). The chemical and photophysical properties of the complexes formed between L and mono‐, di‐, and trinitrobenzene, and di‐ and trinitrotoluene were studied in acetonitrile and chloroform by using 1 H NMR, UV/Vis, and fluorescence spectroscopy. Fluorescence spectroscopy revealed that the trinitroaromatics engendered the largest response among the various substrates tested, with the sensitivity for these analytes being correspondingly high. Quantitative analysis of the fluorescence titration profile generated from the titration of L with TNT provided evidence that this particular functionalized calix[4]arene receptor allows for the detection of TNT down to the low ppb level in CH 3 CN. A single‐crystal X‐ray diffraction analysis revealed that in the solid state the complex L⋅TNT consists of a supramolecular crystalline polymeric structure, the formation of which appears to be driven by intermolecular π–π interactions between two pyrene units and a TNT molecule held at a distance of 3.2–3.6 Å, as well as by intra‐ and intermolecular hydrogen‐bonds among the amide linkages. Nevertheless, the changes in the 1 H NMR, UV/Vis, and fluorescence spectrum, including sharp color changes, are ascribed to a charge‐transfer interaction arising from complementary π–π overlap between the pyrene subunits and the bound trinitroaromatic substrates. A number of ab initio calculations were also carried out and, considered in concert, they provide further support for the proposed charge‐transfer interactions, particularly in the case of L⋅TNT.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fluorescence based explosive detection: from mechanisms to sensory materials
Sun, X., Wang, Y., & Lei, Y. (2015) · Chemical Society Reviews · doi:10.1039/c5cs00496a · Cited by 1,243
Revisiting Fluorescent Calixarenes: From Molecular Sensors to Smart Materials
Kumar, R., Sharma, A., Singh, H., Suating, P., Kim, H. S., Sunwoo, K., Shim, I., Gibb, B. C., & Kim, J. S. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00605 · Cited by 538
Self-citationCrawford, A. G., Dwyer, A. D., Liu, Z., Steffen, A., Beeby, A., Pålsson, L.-O., Tozer, D. J., & Marder, T. B. (2011) · Journal of the American Chemical Society · doi:10.1021/ja2006862 · Cited by 375
Metadata
- Authors
- Lee, Y. H., Liu, H., Lee, J. Y., Kim, S. H., Kim, S. K., Sessler, J. L., Kim, Y., & Kim, J. S.
- Venue
- Chemistry – A European Journal
- Publisher
- Wiley
- Published
- 2010-05-14
- Volume
- 16
- Issue
- 20
- Pages
- 5895-5901
- ISSN
- 0947-6539 (ISSN-L)
- 1521-3765
- OpenAlex
- W2163534008
- Cited by
- 185
- References
- 0
- FWCI
- 8.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dipyrenylcalix[4]arene—A Fluorescence‐Based Chemosensor for Trinitroaromatic Explosives. https://app.cochat.ai/papers/10.1002/chem.200903439
- The paper
- Lee, Y. H., Liu, H., Lee, J. Y., Kim, S. H., Kim, S. K., Sessler, J. L., Kim, Y., & Kim, J. S. (2010). Dipyrenylcalix[4]arene—A Fluorescence‐Based Chemosensor for Trinitroaromatic Explosives. Chemistry – A European Journal. https://doi.org/10.1002/chem.200903439
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.