The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Near‐Infrared Cell‐Permeable Hg2+‐Selective Ratiometric Fluorescent Chemodosimeters and Fast Indicator Paper for MeHg+ Based on Tricarbocyanines
Abstract
Three tricarbocyanine dyes (IR‐897, IR‐877, and IR‐925) with different thiourea substituents that function as dosimeter units through specific Hg 2+‐induced desulfurization have been demonstrated in a fast indicator paper for Hg 2+ and MeHg+ ions. In comparison with available Hg 2+‐selective chemodosimeters, IR‐897 and IR‐877 show several advantages, such as convenient synthesis, very long wavelengths falling in the near‐infrared (NIR) region (650–900 nm) with high molar extinction coefficients, a ratiometric response, and quite low disturbance with Ag+ and Cu 2+ ions. They exhibit large redshifts, which result in a clear color change from deep blue to pea green that can be easily monitored by the naked eye for a convenient indicator paper. In emission spectra, they display a characteristic turn‐off mode at 780 nm and turn‐on mode at 830 nm with titration of Hg 2+ ions. Remarkably, the signal/noise (S/N) ratio with other thiophilic metal ions (Ag+ and Cu 2+) is greatly enhanced with ratiometric measurement of two channels: excitation spectra mode (I810 nm/I670 nm, monitored at 830 nm) and emission spectra mode (I830 nm/I780 nm, isosbestic absorption point at 730 nm as excitation). The distinct response is dependent upon the electron‐donating effect of the thiourea substituents; that is, the stronger the electron‐donating capability of the thiourea substituents, the faster the Hg 2+‐promoted cyclization. Additionally, experiments with living SW1116 cells show that these three tricarbocyanine dyes with low toxicity can exhibit special characteristics that are favorable for visualizing intracellular Hg 2+ and MeHg+ ions in biological systems, including excellent membrane permeability, minimal interfering absorption and fluorescence from biological samples, low scattering, and deep penetration into tissues.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The toxicology of mercury—current exposures and clinical manifestations
Clarkson, T. W., Magos, L., & Myers, G. J. (2003) · New England Journal of Medicine · doi:10.1056/nejmra022471 · Cited by 1,766
Cited by
Luminescent Chemodosimeters for Bioimaging
Yang, Y., Zhao, Q., Feng, W., & Li, F. (2013) · Chemical Reviews · doi:10.1021/cr2004103 · Cited by 2,236
Reaction-based small-molecule fluorescent probes for chemoselective bioimaging
Chan, J., Dodani, S. C., & Chang, C. J. (2012) · Nature Chemistry · doi:10.1038/nchem.1500 · Cited by 1,883
Yuan, L., Lin, W., Zheng, K., He, L., & Huang, W. (2013) · Chem. Soc. Rev. · doi:10.1039/c2cs35313j · Cited by 1,822
Recent progress in the development of near-infrared fluorescent probes for bioimaging applications
Guo, Z., Park, S., Yoon, J., & Shin, I. (2014) · Chem. Soc. Rev. · doi:10.1039/c3cs60271k · Cited by 1,801
Self-citationDesign Strategies for Water-Soluble Small Molecular Chromogenic and Fluorogenic Probes
Li, X., Gao, X., Shi, W., & Ma, H. (2014) · Chemical Reviews · doi:10.1021/cr300508p · Cited by 1,729
Metadata
- Authors
- Guo, Z., Zhu, W., Zhu, M., Wu, X., & Tian, H.
- Venue
- Chemistry – A European Journal
- Publisher
- Wiley
- Published
- 2010-10-29
- Volume
- 16
- Issue
- 48
- Pages
- 14424-14432
- ISSN
- 0947-6539 (ISSN-L)
- 1521-3765
- OpenAlex
- W1985241870
- Cited by
- 169
- References
- 1
- FWCI
- 9.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Near‐Infrared Cell‐Permeable Hg2+‐Selective Ratiometric Fluorescent Chemodosimeters and Fast Indicator Paper for MeHg+ Based on Tricarbocyanines. https://app.cochat.ai/papers/10.1002/chem.201001769
- The paper
- Guo, Z., Zhu, W., Zhu, M., Wu, X., & Tian, H. (2010). Near‐Infrared Cell‐Permeable Hg2+‐Selective Ratiometric Fluorescent Chemodosimeters and Fast Indicator Paper for MeHg+ Based on Tricarbocyanines. Chemistry – A European Journal. https://doi.org/10.1002/chem.201001769
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.